Informations sur l'appareil:

Fluke 1912A Compteur de fréquence
Fabricant:
Fluke
Modèle: 1912A
Date: 1977
Catégorie: Mètres
Groupe: Compteur de fréquence
Description: Multi-Counter
Information:
                                    These rugged counters are at home on the production line, in the lab, or in the field and do the work of counters costing much more. They measure frequencies to 125 MHz, 250 MHz or 520 MHz (depending on model), period of signals to 2 MHz, period average to 10 ps resolution and totalize to 9,999,999 counts. Autorange Full autoranging is supplemented by selectable four-range manual operation. In autorange, the display is automatically filled to a maximum 7-digit readout. A unique hysteresis capability eliminates undesirable up-and-down ranging for between-range signals. Autoreset This automatic feature is activated every time you select a new range orfunction, which means you never have to wait for a second reading, the first one in the new measurement sequence is always correct. Autoreset saves time and reduces errors. Automatic Clean Dropout The 1911A and 1912A Channel B input has a circuit which automatically monitors the input and gives you instant warning in the form of zero readout whenever your input signal falls below the sensitivity threshold of the trigger circuit. When the signal level returns to an acceptable level, the counter locks on for a correct reading. Sensitivity A basic sensitivity of 15 mV, backed by Fluke’s conservative design margin, guarantees you will get reliable, solid readings every time. In practice, a typical sensitivity of 10 mV will be experienced. Versatile Time Bases The standard 0.5 ppm per month timebase assures excellent long term stability for bench, production or field use. A convenient rear panel external timebase input jack and switch let you operate from your own 10 MHz frequency standard at any time. Choice of optional time bases with improved aging rates and temperature stabilities allows you to purchase only as much stability as you’ll need in your applications. Input Signal Conditioning Each counter offers trigger level and attenuator controls which operate over the dynamic range of the input to permit accurate readings in the presence of noise. Even ringing TTL signals can be accurately measured. In addition, the 1911A offers a separate 50 ohm input for 50 MHz to 250 MHz and the 1912A does the same but goes to 520 MHz. Battery Portability All three counters are available with rechargeable batteries for field portability. Order 1910A -01,1911A-01, or 1912-01. Four hours minimum operation gives you plenty of opportunity to solve those tough field service problems

Les guides suivants sont disponibles pour l'équipement ci-dessus:

Fluke -- 1912A -- Manuel de l'utilisateur et Schéma cirquit
Nom du fichier: Fluke-1431-Manual-Page-1-Picture
Type de document: Manuel de l'utilisateur et Schéma cirquit
Nombre de pages: 130
Taille du fichier: 4.80 Mbytes (5028696 Bytes)
langue: anglaise
Révision: 1 2/79
Document ID/Numéro: 467746
Date: September 1977
qualité: Document scanné, tous les lisible.
Chargé sur:
MD5: bee6ced69acf87eef54dbb1fc019a3be
ed2kID: f368afed9b43be5cf697dd4e34753c49
Téléchargements: 998 depuis 19 February 2009
Information:
Fluke-1431-Manual-Page-1-Picture
Télécharger maintenant gratuit


Fluke -- 1912A -- Fiche technique
Nom du fichier: Fluke-7630-Manual-Page-1-Picture
Type de document: Fiche technique
Nombre de pages: 2
Taille du fichier: 301.43 Kbytes (308661 Bytes)
langue: anglaise
Révision:
Document ID/Numéro:
Date: 1990
qualité: Document scanné, la lecture en partie mal, en partie illisible.
Chargé sur:
MD5: 8fe721a4306641735f88fd786be0f3f8
ed2kID: 886d5382712da388373fc211949ee288
Téléchargements: 49 depuis 28 January 2016
Information:
Fluke-7630-Manual-Page-1-Picture
Télécharger maintenant gratuit


Commentaires

Pas encore de commentaires.

Ajouter un Commentaire

* Informations obligatoires
(ne sera pas publiée)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Out of 56, 14 or 27, which is the smallest?
 
Entrez la réponse:
 
Avertissez-moi des nouveaux commentaires par e-mail.
 
Se souvenir de moi sur cet ordinateur.
 
 
Powered by Commentics