Keithley 2182A Multimètre numérique
Fabricant:
Modèle:
2182A
Date:
2017
Catégorie:
Groupe:
Description:
Nanovoltmeter

Information

The Model 2182 is a 7 1⁄2-digit high-performance digital nanovoltmeter. It has two input channels to measure voltage and temperature. The measurement capabilities of the Model 2182 are explained in Section 2 of this manual (see “Measurement overview”). Features of the Model 2182 Nanovoltmeter include: • Ratio — Provides comparison readings between two voltage inputs. Ratio performs V1/V2. • Delta — Provides average difference of Channel 1 inputs. Delta performs (V1t1–V1t2)/2. • Enhanced Delta, Pulse Delta, and Differential Conductance — The following tests can be performed when using a Model 2182 2182A/with a Model 6220 or 6221 Current Source: — Delta - Uses a square wave output and a 3-point measurement algorithm to cancel the effects of thermal EMFs. — Pulse Delta /6221 and 2182A only) - Provides a pulse output and a 3-point (or 2-point) measurement algorithm for testing of temperature sensitive Device Under Test (DUT). — Differential Conductance - Uses a differential current output and a 3-point moving average algorithm to perform differential measurements. • mX+b and Percent — These calculations provide mathematical manipulation of readings. • Relative — Null offsets or establish baseline values. • Buffer — Store up to 1024 readings in the internal buffer. • Limits — Set high and low reading limits to test devices. • Internal Scanning — Scan the two input channels of the Model 2182, • External Scanning — Scan the channels or matrix points of Keithley Model 7001.7002 switching cards. • Setup Storage — Two instrument setups (user and factory defaults) can be saved and recalled. • Analog Output — With analog output gain set to one, a full range input will result in a 1V analog output. • Remote Interface — The Model 2182 can be controlled using the IEEE-488 Interface (GPIB) or the RS-232 Interface. • GPIB Programming Language — When using the GPIB, the instrument can be programmed using the SCPI or model 182 (DDCs) programming language. • Closed-cover Calibration — The Model 2182 can be calibrated from either the front panel or the GPIB.

plus

Manuel de l'utilisateur
Type manuel:
Manuel de l'utilisateur
Pages:
339
Taille:
1.97 Mbytes (2066487 Bytes)
Langue:
english
Révision:
B
Manuel-ID:
2182A-900-01
Date:
2017 05 01
Qualité:
Électronique de documents, numérisation sans, bien lisible.
Date de transfert:
2018 08 22
MD5:
fafdfed71d7a8e85ec9b88b59893d53b
Téléchargements:
1201

Information

This User’s Manual supports both the Models 2182 and(2182A: References to the Model 2182 apply to both the Models 2182 and 2182A, References to the Model 2182.2182A apply to the Model 2182 with firmaware version A10 or higher, and the Model 2182A with firmware version C01 or higher. References to the Model 2182A applies to the Model 2182A with firmware version C01 or higher.

plus