Solartron 1260 Analyzer
Fabricant:
Modèle:
1260
Date:
1987
Catégorie:
Groupe:
Description:
IMPEDANCE/ GAIN-PHASE ANALYZER

Information

The 1260 Impedance/Gain-Phase Analyzer uses powerful microprocessor-controlled digital and analog techniques to provide a comprehensive range of impedance and frequency response measuring facilities. These include: ► Single sine drive and analysis of the system or component under test over the frequency range 10μHz to 32MHz. t Measurement integration, and auto-integration, of the Analyzer input, for harmonic and noise rejection. ► Sweep facility, for any one of three measurement variables, frequency, amplitude, or bias. ► A comprehensive range of voltage and current transfer characteristics, each one available from the original base data, which includes: • polar, log polar, and Cartesian coordinates of the voltage measurement result, • polar and cartesian coordinates of current transfer characteristics, • polar and cartesian coordinates of impedance and admittance, • inductance or capacitance values, with resistance, quality factor, or dissipation factor, for series or parallel circuits. ► Plotter output, of immediate or filed data, to a digital plotter on the GPIB. » Limit check and data reduction facility. Data output can be confined to those results that fail within, or outside, user-defined values. ► Output ports selectable from: RS 423, GPIB, and the History File. ► Result scaling, that includes: a normalization facility „that separates the desired results from confusing background data; and, for impedance measurements, a nulling facility that compensates for stray capacitance and inductance. ► Vernier facility, which allows the drive to be adjusted whilst measurements are being made. ► Learn program facility, which allows the instrument to learn a series of control settings and commands. ► Component sorting, manual or automatic. ► Self test facility, ► Local control from a simplified key panel, or remote control from the GPIB.

plus

Manuel de l'utilisateur
Type manuel:
Manuel de l'utilisateur
Pages:
295
Taille:
8.19 Mbytes (8587898 Bytes)
Langue:
english
Révision:
A
Manuel-ID:
12600012
Date:
Qualité:
Document scanné, la lecture en partie mal, en partie illisible.
Date de transfert:
2015 11 15
MD5:
03930813c28164aef531a59445c78873
Téléchargements:
1282

Information

2 Describes how to install the instrument. This procedure should be followed implicitly, to ensure safe and reliable operation of the intrurnent. 3 Introduces the front panel controls and, by means of simple examples, shows you how to start using the instrument. 4 Summarises the control menus. This information, which also appears on a blue pull-out card at the front of the manual, is intended as a memory aid for experienced users. 5 Is an encyclopedia of menu terms and explains the meaning and background of each individual control setting. 6 Explains how to connect the instrument to the item under test. 7 Gives detailed information on how to control the instrument remotely, from the GPIB. Guidance in the use of RS 423 is given also. 9 Lists the error messages. Error messages are displayed (and an error code is output to a remote device) when a bad command has been given to the instrument or an unacceptable control condition exists. 10 Shows how the measurement results may be scaled and/or limits checked. 11 Shows how the instrument may be made to store a series of commands, to be executed later as a learnt program,

plus

manuel de réparation
Type manuel:
manuel de réparation
Pages:
120
Taille:
4.81 Mbytes (5040193 Bytes)
Langue:
english
Révision:
Manuel-ID:
Date:
Qualité:
Document scanné, la lecture en partie mal, en partie illisible.
Date de transfert:
2015 11 15
MD5:
1e4af550459ed0f5cae920d5a5c5b2a2
Téléchargements:
1216

Information

MAINTENANCE MANUAL Volume 2 1 GENERAL 7.3 2 PCB LOCATIONS 7.3 3 ACCESS TO PCBs AN D COMPONENTS 7.4 3.1 Top Cover Removal 7.5 3.2 Bottom Cover Removal 7.6 4 PCB AND COMPONENT REMOVAL 7.6 4.1 Pcb 2 Front Panel Interface 7.7 4.2 Peb 31 Current-to-voltage Converter 7.8 4.5 Membrain Switch Panel 7.8 4.6 Fan 7.9 4.7 Pcb 5 (Power Fail) 7.10 4.8 Power Supply 7.10 4.9 Mother board 7.10 Fig. 7.1 1255 Pcb Locations 7.1 7.2 1260 Pcb Locations 7.4 7.3 Top Cover Removal 7.5 7.4 Remo val of Front Panel Assembly 7.6 7.5 Removal of Front Panel Interface 7.7 7.6 Pcbs 31 and 2 on Front Panel Assembly 7.8 7.7 Component Removal 7.9

plus

manuel de réparation
Type manuel:
manuel de réparation
Pages:
245
Taille:
7.56 Mbytes (7924193 Bytes)
Langue:
english
Révision:
4A
Manuel-ID:
12600013
Date:
Qualité:
Document scanné, la lecture en partie mal, en partie illisible.
Date de transfert:
2015 11 15
MD5:
2c8c3cb6c2b320f43af37f35501f1ed4
Téléchargements:
1453

Information

MAINTENANCE MANUAL Volume 1 1 INTRODUCTION TO THE 1235-60 1 General ... 1.3 2 Safety ... 1.3 2 SYSTEM DESCRIPTION 1 General ... 2.3 2 System Configuration ... 2.3 3 System Control ... 2.3 4 Power-up State ... 2.3 5 Command Structure ... 2.3 6 Stimulus Signal Generation ... 2.4 7 Signal Analysis ... 2.4 8 Post Analysis Data Processing and Output Data Control ... 2.5 9 PCB Locations ... 2.5 3 1255-60 BUS 1 General ... 3.3 2 1250 Bus Configuration ... 3.3 3 Device Address and Data Bus ... 3.3 4 Processor Interrupt ... 3.4 5 Board Presence ... 3.4 6 Device Request ... 3.4 7 Bus Timing ... 3.4 B DC Supply Lines ... 3.4 4 SELF TEST FACILITIES 1 Introduction ... 4.3 2 Memory Map ... 4.3 3 Power up ... 4.3 4 Break ... 4.3 5 The Seif Test Facility ... 4.4 6 SelfTest Details ... 4.7 7 The Processor Boards Leds ... 4.11 5 BOARD DESCRIPTIONS 1 Foreword ... 5.3 2 Front Panel Interface (PCB2) ... 5.4 3 Power Fail Detect (PCB5) ... 5.11 4 High Frequency Analyzer (PCB 10) ... 5.13 5 High Frequency Generator (PCB14) ... 5.23 6 Generator (PCB15) ... 5.27 7 HF Sythesizer (PCB16) ... 5.33 8 Analyzer Controller (PCB17) ... 5.37 9 Sythesizer (PCB18) ... 5.43 10 Main Processor (PCB22) ... 5.47 11 Current-to-Voltage Converter (PCB31) ... 5.55 6 CALIBRATION OF 1255 & 1260 A Calibration of 1255 ... 6.1 B Calibration of 1260 ... 6.53

plus