Advantest Corporation TR4172 Analizador de espectro
Fabricante:
Modelo:
TR4172
Fecha:
1982
Categoría:
Grupo:
Descripción:

Información

The TR4172 spectrum Analyzer is a microprocessor-controlled, intelligent instrument with a frequency range from 50 Hz to 1800 MHz. in addition to the spectrum analyzing function, the integrated tracking Generator of TR4172 enables analysis of frequency response of filters, amplifiers, and so on. TR4172 is the first spectrum Analyzer with a capability for measuring phase response and group delay of filters or amplifiers at resolutions of down to 0.1 deg and 0.1 ns respectively, up to a frequency of 1800 MHZ. The integrated tracking Generator, along with the analyzer’ร intelligent control capability, permits correction of the analyzer's frequency response itself allowing precision level measurement. A wide dynamic range is ensured by the low higher-harmonic distortion level of 90 dB at and above 20 MHz, with respect to a signal level of -40 dBm. The display screen has a dynamic range of more than 95 dB and permits direct observation of Filter responses with large attenuations. The vertical resolution of the scale can be selected from 10, 5, 2, 1, and 0.1 dB per division, observation of a ripple level of even 0.01 dB is possible with the maximum resolution setting. Use of the SAVE switch makes various measurements available, with which up to eight sets of measurement condition data are stored in the internal registers and recalled as needed. Since the internal memory is backed up by a battery, its contents remain intact even if the device is unplugged from its supply outlet. All front panel functions are remotely controllable with the GPIB Interface (standard supply) for automatic measurement. The CRT display presents all pertinent measurement data. The signal response trace and measurement data on the screen can be output to an X-Y plotter simply by connecting the instrument*ร GPIB connector to the plotter'ร input with a GPIB cable and operating the relevant front-panel switches, without the need for running an output program on the GPIB controller. TR4172 also provides various convenient features to enhance measurement flexibility and efficiency, such as multiple marker, zoom, automatic centering, automatic enlargement, auto-peak search, logarithmic scaling, and four page memorized display. 1-2. FEATURES (1) Spectrum, amplitude, phase and group-delay measurement capability at resolutions of down to 10 Hz, 0.1 dB/div., 0.2 deg/div., and 0.1 ns/div. respectively. (2) Wide dynamic range of 90 dB at “40 dBm input level (above 20 MHz). (3) CRT screen with a large display dynamic range of more than 95 dB permitting direct observation of large attenuation responses. (4) Simultaneous four trace display allowing waveform comparison. (5) Multiple marker. (6) Automatic correction of bandwidth switching error, step Amplifier switching error, and frequency response error. (7) Scaling the horizontal graticule divisions in logarithmic scale. (8) Output to an X-Y plotter supported without the need for the external GPIB controller. (9) Remote operation of all front panel functions via the external GPIB Interface facility (standard supply). Reading capability for measurement data and labels on the screen and writing capability for characters and data on the screen.

ver más

Manual del usuario
Type manuel:
Manual del usuario
Páginas:
1092
Tamaño:
11.29 Mbytes (11835089 Bytes)
Idioma:
english
Revisión:
first edition
Manuel-ID:
ED01 9509
Fecha:
1982 09 01
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2013 01 13
MD5:
02b203762181a34cdffb85707f300145
Descargas:
1111
Manual del usuario
Type manuel:
Manual del usuario
Páginas:
34
Tamaño:
483.46 Kbytes (495066 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
Fecha:
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2013 01 13
MD5:
47bc365ef65d983e2b0158dc9dc263fa
Descargas:
2059

Información

Connection Manuals TABLE OF CONTENTS 1. CONNECTION ... 1 - 1 1.1 MODIFICATIONS OF TR4172.4173 FOR CONNECTION OF TR14501A.B ... 1-1 1.2 PARTS FOR MODIFICATION OF TR4172.4173 ... 1 - 2 1.3 MODIFICATION PROCEDURE ... 1 - 3 2. ADJUSTMENT AND INSPECTION ... 2 - 1 2.1 INTRODUCTION OF TR14501A.B ADJUSTMENT ... 2 - 1 2.2 CHECK AND ADJUSTMENT BEFORE POWER ON ... 2 - 2 2.2.1 Check before Power on ... 2 - 2 2.2.2 Check and Adjustment after Power on ... 2 - 3 2.3 UNIT TEST OF TR14501A.B BY MEANS OF TEST LEDs ... 2-4 2.3.1 Function of Each LED ... 2 - 4 2.3.2 TR14501 A/B Unit Check by Test LEDs ... 2 - 4 2.3.3 Initial Check ... 2 - 5 2.3.4 Key Code Check ... 2 - 7 2.4 LOGIC CIRCUIT FUNCTION CHECK BY USING GPIB ... 2 - 8 2.4.1 Necessary Devices {Included in Necessary Devices for Specification Inspection) ... 2 - 8 2.4.2 Tested Items ... 2 - 8 2.4.3 Operation ... 2 - 9 2.5 TR14501A/B SPECIFICATION INSPECTION ... 2 - 10 2.5.1 Characteristics to be Inspected ... 2 - 10 2.5.2 Necessary Devices ... 2 - 14 2.5.3 Operation ... 2 - 15

ver más

Manual del usuario
Type manuel:
Manual del usuario
Páginas:
294
Tamaño:
7.94 Mbytes (8327713 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
Fecha:
Formato:
Documento Scaneds, en parte leyendo mal, no parcialmente legible.
Fecha de subida:
2016 08 17
MD5:
66c6e447836ddf52c0d9b0b5f7295204
Descargas:
601
Manual de servicio
Type manuel:
Manual de servicio
Páginas:
186
Tamaño:
6.22 Mbytes (6523010 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
EAOO 8704
Fecha:
1982 09 01
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2016 08 17
MD5:
715194f423367f47f7c9fc7bdc09f1d8
Descargas:
577

Información

Volume 2 Parts List

ver más

Manual del usuario
Type manuel:
Manual del usuario
Páginas:
1195
Tamaño:
22.57 Mbytes (23668881 Bytes)
Idioma:
english
Revisión:
First Printing
Manuel-ID:
ED01 9509
Fecha:
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2014 04 22
MD5:
8f19f6b9a4e8e59fb7ceb28489d97180
Descargas:
970

Información

INSTRUCTION MANUAL Vol I

ver más