Associated Research Incorporated 5060AT Test Set
Fabricante:
Modelo:
5060AT
Fecha:
Categoría:
Grupo:
Descripción:
GROUND CONTINUITY TEST SET

Información

Wide, easy reading 4-1/2 inch kilovoltmeter with 2* of fu]l sca]e accuracy.

ver más

Servicio y Manual del usuario
Type manuel:
Servicio y Manual del usuario
Páginas:
46
Tamaño:
1.53 Mbytes (1599656 Bytes)
Idioma:
english
Revisión:
C
Manuel-ID:
36604
Fecha:
Formato:
Documento Scaneds, en parte leyendo mal, no parcialmente legible.
Fecha de subida:
2017 10 21
MD5:
5ad0a92374633741b441bae27a1aa5f7
Descargas:
3395

Información

This manual discusses the reasons dielectric withstand tests are required, the precautions necessary to ensure that the tests are done safely, and how such tests are accomplished on various classes of materials, components and products. In later chapters, the features of Associated Research 4000 and 5000 Series Hypots® are explained, along with a step by step guide to their proper use. Finally, technical data is presented for all models. Associated Research, Inc., has been manufacturing High Voltage Testing Instruments since 1936. Our line of Dielectric Withstand Testers (Hypots©) is the broadest line available today. These products are based upon designs from the early 1940’s when AR manufactured the first commercial Hypot tester for Electric Motor Division of General Motors. These instruments have gone through several generations of design improvements, building on reliable, field proven technology and contain the features and benefits our customers have requested.

ver más

Servicio y Manual del usuario
Type manuel:
Servicio y Manual del usuario
Páginas:
26
Tamaño:
653.48 Kbytes (669166 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
Fecha:
Formato:
Documento Scaneds, en parte leyendo mal, no parcialmente legible.
Fecha de subida:
2017 10 21
MD5:
73547756162e0abceb967e2e825d47b8
Descargas:
343

Información

Introduction ... ... 3 Safety Precautions Required for High Voltage Testing 4 Why Perform Dielectric Withstand Tests? ... 5 Typical Applications ... 6 Features of Model 05060AT ... 8 Manual Operating Instructions ... 11 One Second Timer Operating Instructions ... 12 Line Monitor ”D0 NOT OPERATE" Conditions ... 15 Current Trip (Sensitivity) Adjustment ... 1 i- Model 0506DAT Specifications ... 16 Schematic Wiring Diagram ... 16 Replacement Parts List ... 19 Limited Warranty £ Owner's Registration Card ... Ins* ice Rear Cover