Kikusui Electronics Corporation AVM23 Multímetro digital
Fabricante:
Modelo:
AVM23
Fecha:
2001
Categoría:
Grupo:
Descripción:
AC Voltmeter

Información

These AC Voltmeters are capable of measuring AC voltages of 10 Hz - 500 kHz. The response characteristics of the pointers are of mean-value response. The scales are calibrated with root-mean—square values for sinusoidal waveform inputs.. Range selection of the Dual-pointer Voltmeters (Models AVM23 AVM25 AVM23R , and AVM25R) can be made with, the two channels directly linked together or with the two channels linked together providing a certain differential level between them, as well as it can be made independently for each of the two channels. Also» these, models of voltmeters are incorporated with a GND MODE selector so that the circuit ground can be connected to or floated from the case ground. Models AVM23R and AVM25R Voltmeters are capable of remote control of range selection.. The remote control signal used for this purpose is a positive-logic TTL-level binary-coded signal with 4 bits per channel. The Remote Controllers which can be used for this purpose are RC01-AVM, RC02-AVM, RCOl-ORC, and RC02-ORC, When the IF01-AVM (GP-IB interface) is used, digital data corresponding to pointer deflection can be sent to the CPU making use of the range selection control signal and DC output signal of the voltmeter. All of the six models of Voltmeters are provided with an AC output terminal which delivers an output signal of approximately CL.1 V rms for full scale. Models AVM23R and AVM25R Voltmeters are provided with a DC output terminal which delivers an output signal of 1 V (±3%) for full scale..

ver más

Servicio y Manual del usuario
Type manuel:
Servicio y Manual del usuario
Páginas:
35
Tamaño:
2.16 Mbytes (2264145 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
Z1-111-120, IA001812
Fecha:
2001 01 01
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2017 09 02
MD5:
4ccbae14531d765a090754072083344f
Descargas:
2390

Información

1. GENERAL . , ... 1 2. SPECIFICATIONS ... , ... 3 2.1 Specifications Common to All. Models ., ... 3 2.2 Power Consumptions and Weights- ... 4 2.3 Measuring Voltage Ranges 4 2.4 Maximum Allowable Input Overvoltages- ... 4 2.5 Isolation of Circuit Ground from Case Ground 5 2.6 DC Output ... 5 2.7 Remote Control of Range Selection ... 5 3. NOTES BEFORE USE ... 7 3.1 Unpacking and Inspection . ... 7 3.2 AC Line Voltage ... 7 3.3 Operating Environments ... 8 3.4 Mechanical Zero Adjustment of Indicating Meter ... 8 3.5 GND MODE Switch. [Dual-pointer Models] ... 8 3.6 Circuit Ground and Case Ground ... 9 3.7 Remote Control Connector [AV23R, 25R] ... 9 3.8 Others ... 10 4. OPERATION METHOD ... 14 4.1 Description of Front Panel Items ... , ... 14 4 .2 Description of Rear Panel Items ... . 16 4.3 Measuring Procedure ... 18 4.4 Frequency Range for Guaranteed Accuracy ... 18 4.5 Signal Waveforms and Indication Errors ... 19 4.6 Remote Control of Range Selection [AV23R, 25R] 20 5. MAINTENANCE ... 26 5.1 Meter Cover ... 26 5.2 Adjustment and Calibration 26 5.3 Others. ... 31

ver más