Equipment information:

Hewlett Packard 3586A Level Meter
Manufacturer:
Hewlett Packard
Model: 3586A
Date: 1979
Category: Measurement instruments
Group: Level Meter
Description: Selective Level Meter
Information:
                                    The 3586A/B Selective Level Meter is designed for use in the design, manufacture, installation, and maintenance of Frequency Division Multiplex (FDM) systems and for general purpose wave analysis and frequency synthesis. The 3586A is available to meet the needs of C.C.I.T.T. requirements, while the 3586B meets North American (Bell) Standards. The 3586C is a general purpose instrument.

The 3586A/B provides the ability to make both carrier frequency measurements to 32.5MHz and voice channel measurements from 50Hz to 100kHz.

The Transmission impairments Option 003 allows the user to quickly troubleshoot voice channel problems with phase jitter, noise-with-tone, signal-to-noise-with-tone-ratio, and single level impulse noise measurements, all with one instrument. The capability to make all these transmission impairment measurements combined with both FDM voice channel and carrier frequency measurements is available only on the 3586A/B. Standard models include a 1740Hz psophometric or 2000Hz C-message equivalent noise filter, or weighted noise measurements can be made directly with the 3100Hz channel filter and noise weighting filter provided with the Transmission Impairments Option 003. Filter shape factor of < 1.2 provides 60dB carrier and 75dB adjacent channel rejection.

These manuals are available for the above equipment:

Hewlett Packard -- 3586A -- Service Manual
File name: HewlettPackard-4893-Manual-Page-1-Picture
Manual Type: Service Manual
Pages: 258
Size: 24.89 Mbytes (26096342 Bytes)
Language: english
Revision:
Manual-ID/Number: 03586-90002V1
Date: May 1983
Quality: Scanned document, all readable.
Upload date:
MD5: 0cd427becc8abaa881d815836a7e46d2
ed2kID: 7f7b7986afddfdefdf00839781c68aef
Downloads: 206 since 23 November 2013
Information:
This manual applies to all instruments. Earlier versions of
the 3586A/B/C, however, may differ in design and appearance
from the instruments this revision documents directly.
Changes that have been made to the instrument and which
affect the instrument's documentation are identified by the
delta (A) symbol. The "numbered" A refers the reader to the
corresponding numbered A in the backdating section (Section
VII) in Volume I of the 3586A/B/C Service Manual.

Service Manual Volume I
HewlettPackard-4893-Manual-Page-1-Picture
Start Free Download


Hewlett Packard -- 3586A -- Service Manual
File name: HewlettPackard-4894-Manual-Page-1-Picture
Manual Type: Service Manual
Pages: 185
Size: 44.42 Mbytes (46579470 Bytes)
Language: english
Revision:
Manual-ID/Number: 03586-90002V2
Date: May 1983
Quality: Scanned document, all readable.
Upload date:
MD5: 137553d35232883d5e2da88fdfcbcf50
ed2kID: e1747296746b1bcdbac88995dc4c0e74
Downloads: 157 since 23 November 2013
Information:
Service Manual Volume II

This manual applies to all instruments. Earlier versions of
the 3586A/B/C, however, may differ in design and appearance
from the instruments this revision documents directly.
Changes that have been made to the instrument and which
affect the instrument's documentation are identified by the
delta (A) symbol. The "numbered" A refers the reader to the
corresponding numbered A in the backdating section (Section
VII) in Volume I of the 3586A/B/C Service Manual.

8-2. This volume of the Service Manual contains information
relative to the maintenance and service of the 3586A/B/C
Selective Level Meter. The information presented in this
manual is assembled into four major segments: Turn-on
Initialization and Milking the Front Panel, Troubleshooting,
Detailed Functional (circuit) Description, and Service
Groups. Where references are made throughout the manual to a
performance test, adjustment procedure, the parts list, or
backdating section, refer to Volume I: 3586 Performance
Tests, Adjustments, Parts, and Backdating. In order to
obtain a minimum of instrument down time and to provide for
the greatest amount of troubleshooting efficiency and
safety, it is recommended that Safety Considerations
(paragraph 8-5), Use Of The Service Manual (paragraph 8-8),
and Service Volume Organization (paragraph 8-11) be read
before initiating any troubleshooting procedures.

HewlettPackard-4894-Manual-Page-1-Picture
Start Free Download


Hewlett Packard -- 3586A -- User Manual
File name: HewlettPackard-4895-Manual-Page-1-Picture
Manual Type: User Manual
Pages: 146
Size: 4.26 Mbytes (4470828 Bytes)
Language: english
Revision:
Manual-ID/Number: 03586-90012
Date: April 1983
Quality: Scanned document, all readable.
Upload date:
MD5: 49036966b1a619c78917cd8eee76af85
ed2kID: 1cd56af1a62560a7f7d202c0799e1e6e
Downloads: 128 since 23 November 2013
Information:
This manual applies to instruments with serial number
prefixed 1927A, 192«A, and 1929A.
HewlettPackard-4895-Manual-Page-1-Picture
Start Free Download


Comments

No comments yet.

Add Comment

* Required information
(never displayed)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Enter the third letter of the word castle.
 
Enter answer:
 
Notify me of new comments via email.
 
Remember my form inputs on this computer.
 
 
Powered by Commentics