Equipment information:

Whirlpool ADG 931/2 NB (8511 931 01360) Dish washer
Model: ADG 931/2 NB (8511 931 01360)
Date: 1998
Category: Home electronics
Group: Dish washer
                                    Technical data

Height 85 cm
Width 44.8 cm
Depth 60 cm
Weight 45 kg

Wooden door
Thickness min.. 16 mm
Thickness max. 25 mm
Width min. 445 mm
Width max. 450 mm
Height min. 571.5 mm
Height max. 604 mm
Weight min. 1.8 kg
Weight max. 5.6 kg
Max. stick out over lower
edge of appliance door 90 mm

Specification / PI-Expression (norm. Progr.)
Detergent 25 gr
by 21 °deg d.H. 28 gr
Water connection up to 60 °C
Capacity 9 stand. place settings


Working-level 3.75 l
- motor on 9.5 l
- motor off 6.5 l
Overflow-level 6.2 l
Detergent 5+25 gr
Clear rinse containing 120 ccm
Rinse dosage per step 1- 6 ccm
Salt container volume 1.35 kg

Flow rates / Inlet volumes
Spray pump ~ 50 l/min
Drain pump ~ 15 l/min
Water inlet electrovalve ~ 3.75 l/min

Water pressure
Inlet pressure min. 0.3 bar
Spraypump pressure 0.3 bar

SP-Motor 2680 RPM
DP-Motor 2500 RPM
Spray arm lower 37 5 RPM
Spray arm upper 24 5 RPM

Electrical Data

Base level
Voltage 220/230 V
Frequency 50 Hz
Total power 2200 W
Fuses 10 A

Model Eaton EC 4707
Basic step times 30’’-1’-2’-4’
Steps 60

Throughflow system
Voltage 220/230 V
Total power 2.05 kW
Resistance 27 W


Voltage 220/230 V
Power consumption 150 W
HI 38 W
HA 40 W
Capacitor 6 F
To loos spraypump
from motor turn anti clockwise
To fit spraypump
on motor turn clockwise
needed racket spanner 6 mm

Voltage 220/230 V
Power consumption 23 W
Resistance 200 W

Timer Motor
Voltage 220/230 V
Power consumption 3.5 W
Resistance 6450 W


Inlet valve
Voltage 220-240 V
Power consumption 6 W
Resistance 3750 W

Regeneration valve
Voltage 220-240 V
Power consumption 6 W
Resistance 3750 W

Safty system against water-leakage
Aquastop + floater switch
Floter switches of the inlet valve and on the drain


Double thermostat in the Door

Color code grey
Temperature 58 °C
closes when temperature is reached

Color code red
Temperature 72 °C
opens when temperature is reached

Water measuring
Remove the coases sieve, put into the sump a
meassuring meter, look the height of the water
Working level 110 mm
Safety level 125 mm


Working level
Niveau 80/60 3 mm

Safety level (against overflow)
Niveau 125/75 3 mm

High pressure pressostat (against heating without
Niveau 2400/1500mm

These manuals are available for the above equipment:

Whirlpool -- ADG 931/2 NB (8511 931 01360) -- Service Manual
File name: Whirlpool-4640-Manual-Page-1-Picture
Manual Type: Service Manual
Pages: 13
Size: 349.28 Kbytes (357665 Bytes)
Language: english
Manual-ID/Number: 4812 718 13883
Date: 12 December 1998
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 3789ce9d6a445dd6cc1d96e108a993ab
ed2kID: 788b457a74b543245488d65b66d70b3d
Downloads: 138 since 03 October 2013
This documentation is only intended for qualified technicians who are aware of the respective
safety regulations.

Technical data 2 - 4
Spare part list 5 - 6
Exploded view 7 - 10
Wiring diagram 11
Circuit diagram 12
Program diagram 13
Start Free Download


No comments yet.

Add Comment

* Required information
(never displayed)
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
Which word in this sentence is bold?
Enter answer:
Notify me of new comments via email.
Remember my form inputs on this computer.
Powered by Commentics