Equipment information:

LeCroy 9400 Oscilloscope
Model: 9400
Date: 1990
Category: Measurement instruments
Group: Oscilloscope
Description: Digital Oscilloscope

These manuals are available for the above equipment:

LeCroy -- 9400 -- Service Manual
File name: LeCroy-4103-Manual-Page-1-Picture
Manual Type: Service Manual
Pages: 432
Size: 13.66 Mbytes (14320484 Bytes)
Language: english
Date: August 1990
Quality: Scanned document, all readable.
Upload date:
MD5: 91b152e18a223df05746a8e7c16e76c4
ed2kID: 71bd9f2859475c5fb47f0841c92921ae
Downloads: 330 since 26 January 2013
The present Service Manual applies to both the 9400 and
the 9400À DSOs. Both models are called 9400 when the
information applies equally to both oscilloscopes.
Where the two models have distinct features, the model
number 9400 or 9400A is explicitly stated.
The chief purpose of this manual is to provide information
for technicians, mainly authorized LeCroy repair office
personnel, who are responsible for repairs and modifications
to the LeCroy 9400/9400A DSOs.
To this end, the descriptions provided are intended to be
of sufficient depth to enable faults to be diagnosed to
the level of the relevant board, so that the customer can
be quickly supported by exchange of boards. In many cases
the fault may be corrected at the local LeCroy office,
but there are several areas of the circuitry where
replacement of a part would need to be followed by
calibration which could be done only with specialized
equipment available at the main LeCroy establishments.
Calibration procedures are given in this manual only
for those areas which could be serviced locally.
A DSO repair intervention at board exchange level
can only be done by qualified technicians who have
followed the basic 9400/9400A service training.
LeCroy also offers these courses to customers. In
addition, there is a very comprehensive 9400 Adjustment
and Calibration Software Package CALS0FT (order codes
CS01/CS02) based on the IBM PC or a compatible computer.
This software package is also available to customers,
as well as all the hardware making up the 9400 Automated
Calibration System (order code CS-S) which is used
in all LeCroy service offices to ensure full performance
of the instrument. This system provides Calibration
Certificates traceable to NBS. LeCroy also offers training
classes on DSO calibration.
This manual could be improved by the inclusion of useful
information resulting from detection and correction
of faults in 9400/9400A DSOs at any LeCroy office.
Each time a DSO is opened, an official LeCroy repair
report should be sent to LeCroy S.A., attention
Customer Service. The information is entered into
a centrally maintained DSO data base for failure
analysis and engineering feedback.
Before undertaking any work on the 9400 DSO you should
read the next sections - WARNINGS and VALID RANGE
Start Free Download


No comments yet.

Add Comment

* Required information
(never displayed)
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
Out of 56, 14 or 27, which is the smallest?
Enter answer:
Notify me of new comments via email.
Remember my form inputs on this computer.
Powered by Commentics