Hewlett Packard 711A Power supply
Manufacturer:
No picture available!
Maybe you can upload a photo for the
Hewlett Packard 711A ?
If you have any other manuals for the
Hewlett Packard 711A you can upload the files here .
Model:
711A
Date:
1965
Category:
Group:
Description:
Information
The Model 711A Power supply is a general-purpose low-power
dc and ac voltage supply particularly suited to powering
experimental setups,
By means of the facilities provided by the Model 711A the
following voltages are made available at the output
terminals on the control panel:
Unregulated ac:
6. 3 volts, 3 amperes maximum load current (two supplies) or
6. 3 volts, 6 amperes maximum load current (one supply) or
12.6 volts, 3 amperes maximum load current (one supply,
tapped at 6. 3V).
Regulated dc:
0 to 500 volts, continuously variable; maximum output load
current, 100 ma.
NOTE: Insulation within the Model 711A permits operating the
dc output voltage as much as 500 volts from chassis ground
so that two Model 711A Power Supplies may be operated in
series to obtain 1000 volts dc output while each instrument
chassis remains at ground potential.
The dc output of the Model 711A has high stability; for line
voltage variations within rated limits, the
level of the regulated output will vary less than 0. 5% or 1
volt (whichever is greater), and from no load to full load
the level of the output will vary less than 0.5% or 1 volt
(whichever is greater). Ripple will be less than 0. 001 volt.
While the internal impedance of the Model 711A will vary
both with the dc load current and the frequency of any
reflections from the equipment being powered, the internal
impedance of the Model 711A will be less than 10 ohms with
any load current and at any frequency up to a few megacycles.
The dc output is continuously monitored by two meters, a
voltmeter and a milliammeter. A low and high range are
provided for each meter so that low values of voltage and
current may be read accurately.
The Power supply is protected from input or output overload
by (1) a fuse in the line-voltage input circuit and (2) a
relay, in the main positive bus, which operates at overload
current to interrupt conduction through the regulator.
Manual type:
Service and User Manual
Pages:
45
Size:
4.77 Mbytes (5006935 Bytes)
Language:
english
Revision:
Manual ID:
00198-3
Date:
1965 07 01
Quality:
Scanned document, all readable.
Upload date:
2017 12 30
MD5:
2bfaf33254a1d3ef2246b035e708f612
Downloads:
500
Information
.
4-8 Power Transformer Primary
Connections ...
4-9 4-10 Troubleshooting Chart ... Trouble
Localization ... .
V REPLACEABLE PARTS ...
5-1 Introduction ...
5-2 Ordering Information ...
5-3 Non-Listed Parts ...
Appendix
A CODE LIST OF MANUFACTURERS
B SALES AND SERVICE OFFICES
C MANUAL BACKDATING CHANGES