Hewlett Packard 606A Generator
Manufacturer:
No picture available!
Maybe you can upload a photo for the
Hewlett Packard 606A ?
If you have any other manuals for the
Hewlett Packard 606A you can upload the files here .
Model:
606A
Date:
1971
Category:
Group:
Description:
High Frequency Signal Generator
Information
The Hewlett-Packard Model 606A is a general-purpose signal
Generator with a frequency range of 50 kHz to 65 MHz. The
instrument has a direct reading frequency dial calibrated to
an accuracy of 1%. Output is held constant within ± 1 dB and
is continuously adjustable from.01 microvolt to 3 volts into
a 50 ohm resistive load. An internal crystal Calibrator
provides check points at 100 kHz and 1 MHz intervals with an
error of less than 0.01%. A front-panel meter accurately
indicates the percent amplitude modulation for frequencies
within the modulation bandwidth of the signal Generator.
The Model 606A has a highly refined amplitude modulation
system which allows modulation up to 90% with low distortion
and incidental FM. This feature makes possible precision
distortion checks of receivers from antenna to output. The
instrument can be internally modulated at 400- or 1000 Hz.
It can be externally modulated from dc to 20kHz or more,
depending on RF frequency in use. Complex waveforms, square
waves, and dc voltages may be used to modulate the Model
606A for testing and evaluating filters, networks,
amplifiers, and receivers.
DIFFERENCES BETWEEN INSTRUMENTS.
The Model 606A carries a five-digit serial number with a
three-digit prefix (000-00000). The prefix changes only when
a change is made in the instrument. The prefix, then, is an
identifier, and it appears on the title page of this manual
to indicate to which instrument this manual directly
applies. A supplement may be included with this manual to
indicate the necessary changes to be made in the manual to
make it apply directly to instruments which carry a
different serial number prefix.
Manual type:
Service and User Manual
Pages:
70
Size:
3.59 Mbytes (3761532 Bytes)
Language:
english
Revision:
Manual ID:
00606-90013
Date:
1971 05 01
Quality:
Scanned document, all readable.
Upload date:
2017 12 30
MD5:
df7ce818f244d664c91c0f49cb0b23fb
Downloads:
443
Information
This manual applies directly to HP Model 606A High Frequency
Signal Generators having serial prefix number 0960A.
I GENERAL INFORMATION ... 1-1
1-1. General Description ... 1-1
1-4. Differences between Instruments . 1-1
1-6. Unpacking and Inspection ... 1-1
1-11. Installation Instructions ... 1-2
1-14. Power Cable ... 1-2
1*16. Accessories Available ... 1-2
II OPERATING INSTRUCTIONS ... 2-1
2-1. Output Termination ... 2-1
2-5. Setting the Cursor ... 2-1
2-7. Output Attenuator ... 2-1
2-9. Use of the 3-Volt Range ... 2-1
2-11. External Modulation ... 2-1
2-13. External Synchronization Signal . 2-1
2-15. B+ Fuse ... 2-1
2-17. Modulation Data ... 2-1
III THEORY OF OPERATION ... 3-1
3-1. Overall Operation ... 3-1
3-3. Circuit Description ... 3-1
IV MAINTENANCE ... 4-1
4-1. Introduction ... 4-1
4-3. Cabinet Removal ... 4-1
4-4. RF Shield Removal ... 4-2
4-5. Test Equipment Required ... 4-2
4-7. Tube Replacement ... 4-3
4-13. Preliminary Check ... 4-3
4-15. Modulation Meter Calibration . . 4-3
4-16. Frequency Calibration ... 4-3
4-18. Output Level Frequency Response 4-3
4-19. Troubleshooting ... 4-9
4-36. Power Supplies ... 4-10
4-42. Audio Oscillator ... 4-10
4-43. Crystal Calibrator ... 4-10
4-44. Tune Oscillator and Amplifier . . 4-10
4-45. Set Maximum Oscillator Current . 4-11
4-46. Carrier Zero Set ... 4-T1
4-47. Maximum Carrier Set and
Modulation Zero Set ... 4-12
4-48. Set Percent Modulation Meter . . . 4-12
4-49. RF Output Meter Calibration . . . 4-12
4-50. Attenuator Repair ... 4-12
4-52. Adjust Feedback Relay ... 4-13
4-54. Drive Cable Assembly Replacement 4-13
4-56. Performance Check ... 4-14
4-58. Frequency Calibration ... 4-14
4-59. Output ... . 4-14
4-60. Modulation ... 4-14
4-61. Frequency Drift ... 4*14
V REPLACEABLE PARTS ... 5-1
5-1. Introduction ... 5-1
5-5. Ordering Information ... 5-1