Associated Research Incorporated Hypot II 3500D Test Set
Manufacturer:
Model:
Hypot II 3500D
Date:
2000
Category:
Group:
Description:
AC ONLY HIPOT WITH GROUND CONTINUITY CHECK

Information

KEY FEATURES & BENEFITS OF Hypot II 1. No load setup of trip current and output voltage. This provides the operator with an easy and safe way to set trip currents and output voltages since parameters are set without the high voltage activated. 2. Automatic storage of test program. Hypot II powers up with the parameters that were used during the last test to avoid operator set-up errors. 3.All parameters for the setups can be adjusted through a simple menu driven program. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 4.Tamper proof front panel controls. This makes it possible to limit user access to the setup screens so that only authorized personnel with a security code can change test parameters. 5.Line and load regulation. This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements.. 6.The LCD display allows monitoring of current down to 100 microamps AC and 20 microamps DC. This allows the Hypot II to be used even when test requirements only allow a very low level of acceptable leakage current. 7.Electronic dwell settings. The electronic dwell control helps keep test results consistent by ensuring that the test duration is the same for each product tested. 8.PLC remote inputs and outputs. The standard 9 pin interfaces provide outputs for Pass, Fail, and Test in Process. Inputs include Test and Reset. This gives the user all the basic remotes required to configure the Hypot II through simple PLC relay control. 9.Front panel LCD displays test parameters and results. A front panel LCD allows the operator to monitor the test. The display holds the results after a test item failure so that the operator can easily review the test results. Indications of high fail and continuity failure are clearly displayed. 10. Maximum output current 12 milliamps AC and 5 milliamps DC. This makes this instrument a true hipot tester with enough output current to test capacitive loads in AC mode and allows the instrument to comply with the UL “120ohm” requirements. 11. Software calibration control. Hypot II is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows Hypot II to be completely calibrated without removing any covers and exposing the technician to hazardous voltages. 12. User selectable output voltage frequencies of 50 or 60 hertz. Hypot II was designed for the global market. This feature makes it simple for the user to select the output frequency in the AC hipot mode so that products can be tested at the same frequency they will be used at. 13. Output voltage fine adjustment. To make Hypot II usable in all types of applications, the operator can manually bring the voltage up or down in 10 volt increments by simply pressing the up and down arrow keys. This makes it very easy to adjust the output voltage even while Hypot II is in the dwell mode so you can analyze test results at different voltages. 14. Built-in Continuity test mode. Hypot II meets ground continuity test requirements called out by UL and other safety agencies. 15. Flashing high voltage indicator. A flashing LED located directly over the high voltage terminal clearly indicates when high voltage is active to provide maximum operator safety. 16. Comes complete with a test box for products terminated in a line cord. The standard US style receptacle box allows easy testing of hipot and continuity on line cord terminated products. As an additional benefit, termination boxes are available for testing products with line cords configured for other countries. 17. User selectable input voltage. Hypot II can be switched for either 115 or 230 volt input operation through an easy access rear panel mounted switch to allow it to be used in any country. 18. Low-current sense. * Monitors the minimum level of current flow, thus ensuring that the DUT is properly connected and that the hipot test is being performed. 19. Electronic ramping. * Provides a gradual and timed method to increase output voltage to the DUT, minimizing any damage from quickly over-applying high voltage to sensitive DUTs. 20.Test setup memories. * The operator can store and recall test setups, thus eliminating the need to re-enter setup information. 21. Insulation Resistance Test Mode ** This allows the operator to perform an Insulation Resistance test independently or in sequence with the Dielectric Withstand (Hipot) test, thus eliminating the need for a separate piece of test equipment when IR testing is required. 22.Insulation Resistance Adjustable Output ** The Insulation Resistance test mode provides an adjustable output range of 100-1000 volts DC. This gives the user the ability to meet most IR test requirements. * Only available on model 3505D, 3565D and 3570D. ** Only available on model 3570D

show more

Service and User Manual
Manual type:
Service and User Manual
Pages:
54
Size:
420.42 Kbytes (430514 Bytes)
Language:
english
Revision:
3.18
Manual ID:
37589
Date:
2000 11 06
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 10 21
MD5:
f10cfe82aaf1d914653cbf6db587aef2
Downloads:
1690

Information

SECTION I OPERATORS MANUAL ... 1 SAFETY ... 2 INTRODUCTION ... 6 SPECIFICATIONS ... 12 CONTROLS ... 18 INSTALLATION ... 21 QUICK START ... 24 OPERATION ... 27 OPTIONS ... 42 SECTION II SERVICE MANUAL ... 45 CALIBRATION ... 46 PARTS LIST ... 49 SCHEMATICS ... 50

show more