Quadtech Inc. Guardian 5000 Analyzer
Manufacturer:
Model:
Guardian 5000
Date:
1999
Category:
Group:
Description:
Safety Analyzer

Information

The Guardian 5000 Safety Analyzer combines four critical safety tests into a single instrument, these being AC hipot, DC hipot, insulation resistance measurements and ground continuity test. The hipot test can be programmed over a voltage range of 0.1 to 5KV AC and 0.5 to 6KV DC with a min/max leakage current detection range of 300μA to 40mA AC and 20mA DC. Insulation resistance measurements are possible to 10GΩ at programmable DC test voltages between 100 and 1000V. A ground continuity test to 30A AC is also possible. The instrument comes standard with internal storage of up to 50 memory groups and an IEEE-488.2 Interface for remote control operation and communication with other instrumentation.

show more

User Manual
Manual type:
User Manual
Pages:
62
Size:
305.94 Kbytes (313280 Bytes)
Language:
english
Revision:
Manual ID:
150206/B3
Date:
1999 11 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 01 29
MD5:
d929709f13aa57c9496813ca62735ed6
Downloads:
583

Information

Warranty ... v Specifications ... vii Introduction - Section 1 1.1 Unpacking and Inspection ... 1-1 1.1 Product Overview ... 1-1 1.3 Front Panel Description ... 1-2 1.4 Rear Panel Description ... 1-6 1.5 Accessories Included ... 1-7 1.6 Accessories/Options Available ... 1-7 1.7 Power Requirements ... 1-8 Operation - Section 2 2.1 Startup ... 2-1 2.2 Instrument Zeroing/Offset ... 2-1 2.3 Connection to Device Under Test ... 2-3 2.4 Measurement Procedure ... 2-6 2.5 Programming Test Modes ... 2-8 2.6 Programming Hipot Test ... 2-10 2.7 Programming Insulation Resistance (IR) Test ... 2-12 2.8 Programming Ground Continuity Test ... 2-14 2.9 Initial Parameter Setting ... 2-16 2.10 Front Panel Lockout ... 2-18 2.11 Software Version Display ... 2-18 2.12 Clear Setup Memory ... 2-18 Input/Output Interfaces - Section 3 3.1 Remote ... 3-1 3.2 IEEE-488 Interface ... 3-3 3.2.1 Description ... 3-3 3.2.2 Interface Commands ... 3-4 3.2.2.1 Listener Functions ... 3-5 3.3.2.2 Talker Functions ... 3-9 3.2.3 Sample QuickBASIC Program ... 3-11 3.3 Scanner Interface ... 3-14 3.3.1 Scanner Accessories ... 3-14 3.3.2 Scanner Card Installation ... 3-14 3.3.3 Scanner Connections ... 3-15 3.3.4 Scanner Programming ... 3-17 3.4 G16 International Power Strip ... 3-19 4.1 General ... 4-1 4.2 Instrument Return ... 4-1 4.3 Calibration ... 4-1 4.3.1 Calibration Procedure ... 4-2 4.3.2 AC Voltage Calibration ... 4-3 4.3.3 DC Voltage Calibration ... 4-4 4.3.4 IR Voltage Calibration ... 4-4 4.3.5 AC Current Calibration ... 4-5 4.3.6 DC Current Calibration ... 4-6 4.3.7 GC Calibration ... 4-7 4.3.8 Finalize Calibration ... 4-8

show more