Ametek Advanced Measurement Technology 5113 Amplifier
Manufacturer
Ametek Advanced Measurement Technology
Model 5113
Date 2002
Category: Measurement instruments
Group Amplifier
Description Low Noise Preamplifier
Information
                                    The Model 5113 Low-Noise Preamplifier provides high gain,
low-noise amplification of wideband signals from DC to 1
MHz, well suited for use with both SIGNAL RECOVERY and other
manufacturers’ signal processing instruments. Adjustable
high and low frequency rolloffs allow the bandwidth to be
reduced. Two inputs, with switchable coupling, allow either
differential or single-ended operation. Coarse gain is
selectable from x5 to x50,000 in a 1-2-5 sequence with a
fine gain control extending the range to xl to X 10,000. An
uncalibrated vernier allows finer adjustment of the gain.

The unit may be powered either from an external DC power
supply or from its internal sealed and maintenance-free
lead-acid batteries. These batteries recharge automatically
when a suitable external power supply is connected. Other
features include an overload fast-recovery button, a
front-panel DC zero screwdriver control, and a battery test
facility.

These manuals are available for the above equipment:

Ametek Advanced Measurement Technology -- 5113 -- User Manual
File name Ametek-8000-Manual-Page-1-Picture
Manual Type User Manual
Pages 39
Size 287.92 Kbytes (294830 Bytes)
Language english
Revision
Manual-ID/Number 222144
Date 01 January 2002
Quality Electronic document, no scan, very well readable.
Upload date
MD5 8fc2006b0be9beda788767712993bef7
Downloads 50 since 03 September 2016
Information
Chapter One, Introduction

1.1	Model 5113
Preamplifier.............................................................................................................................1-1

1.2	Why use a
Preamplifier?.............................................................................................................................1-1

Chapter Two, Installation & Initial Checks

2.1
Installation..................................................................................................................................................2-1

2.1.01
Introduction........................................................................................................................................2-1

2.1.02
Inspection...........................................................................................................................................2-1

2.2	Initial
Checks..............................................................................................................................................2-1

2.2.01
Introduction........................................................................................................................................2-1

2.2.02	Equipment
Required...........................................................................................................................2-1

2.2.03
Procedure...........................................................................................................................................2-2

Chapter Three, Front and Rear Panels

3.1	Front
Panel.................................................................................................................................................3-1

3.1.01	INPUT
Connectors.............................................................................................................................3-1

3.1.01	INPUT COUPLING
Button...............................................................................................................3-1

3.1.03	RECOVER/Sleep
Button....................................................................................................................3-2

3.1.04	GAIN (VERNIER)
Control................................................................................................................3-2

3.1.05	LF ROLL-OFF (SLOPE)
Control.......................................................................................................3-3

3.1.06	HF ROLL-OFF (SLOPE)
Control......................................................................................................3-3

3.1.06	POWER
Switch.................................................................................................................................3-4

3.1.07	OUTPUT
Connector..........................................................................................................................3-4

3.2	Rear
Panel..................................................................................................................................................3-4

Chapter Four, Front Panel Operation

4.1
Introduction................................................................................................................................................4-1

4.2
Operation....................................................................................................................................................4-1

4.2.01
Power.................................................................................................................................................4-1

4.2.02	Signal
Grounding...............................................................................................................................4-1

4.2.03	Signal Voltage and
Gain.....................................................................................................................4-1

4.2.04	DC Zero
Adjustment..........................................................................................................................4-2

4.2.05	Overload Fast
Recovery.....................................................................................................................4-2

4.2.06	Input Mode
Selection..........................................................................................................................4-2

4.2.07	Filter
Selection...................................................................................................................................4-2

4.2.08	Filter
Roll-Off....................................................................................................................................4-3

4.2.09	Special
Pages.....................................................................................................................................4-3

4.2.10	Battery Operation, Test and
Charging.................................................................................................4-4
Chapter Five, Computer Operation

5.1
Introduction.................................................................................................................................................5-1

5.2
Operation....................................................................................................................................................5-1

5.2.01
Overview............................................................................................................................................5-1

5.2.02	RS232 Interface - General
Features.....................................................................................................5-1

5.2.03	Choice of Baud
Rate...........................................................................................................................5-2

5.2.04	RS232 Interface - Command
Format...................................................................................................5-2

5.2	Command
Descriptions................................................................................................................................5-3

Appendix A, Specifications Appendix B, Pinouts Appendix c,
Power Supply Index

Warranty