Equipment information

Fluke 77 Series II Digital multimeter
Manufacturer
Fluke
Model 77 Series II
Date 1997
Category: Measurement instruments
Group Digital multimeter
Description
Information
                                    Maximum Voltage Between any Terminal and Earth Ground
1000V de, 750V ac rms(sine)
Fuse Protection 300 mA. 630 mA, 250V Fast Fuse
10A. 15A, 600V Fast Fuse
Display Digital: 3,200 counts, updates 2.5/sec
Analog: 32 segments, updates 25/sec
Response Time of Digital Display
V ac < 2 s
V do < 1 s
Ω < 1 s to 320 ΚΩ, < 2 s to 3.2 ΜΩ, < 10 s to 32 ΜΩ
Operating Temperature 0°C to 50°C
Storage Temperature -40°C to 60°C
Temperature Coefficient 0.1 x (specified accuracy)/°C (<18°C
or >28°C)
Electromagnetic Compatibility - In an RF field of 3 V/m on
all ranges and functions:
Total Accuracy * Specified Accuracy +1.1% of range
Relative Humidity
Except 32 ΜΩ Range:
Only:
Battery Type Battery Life
Continuity Beeper Shock, Vibration Size (HxWxL)
Weight
Safety
0% to 90% (0°C to 35°C)
0% to 70% (35°C to 50°C)
0% to 80% (0°C to 35°C)
0% to 70% (35°C to 50°C)
9V, NEDA 1604 or 6F22 or 006P 2000 hrs typical with alkaline
1600 hrs typical with carbon zinc 4096 Hz
Per MIL-T-28800 for a Style B, Class 2 Instrument
2.8 cm x 7.5 cm x 16.6 cm (1.12 in x 2.95 in x 6.55 in)
340g (12oz)
Designed to Protection Class II per IEC 348, ANSI/ISA-S82,
UL1244, and CSA C22.2 No.231

These manuals are available for the above equipment:

Fluke -- 77 Series II -- User Manual
File name Fluke-7716-Manual-Page-1-Picture
Manual Type User Manual
Pages 37
Size 8.25 Mbytes (8646768 Bytes)
Language english,german,french
Revision 2
Manual-ID/Number 896191
Date June 1997
Quality Scanned document, all readable.
Upload date
MD5 dd372c97e844cd875a496deb4ec141f3
Downloads 215 since 10 February 2016
Information
WHAT IS IN THIS MANUAL...............................1
SAFETY INFORMATION....................................2
SYMBOLS.............................................................4
ROTARY SWITCH......................................... 5
INPUT
JACKS......................................................6
PUSHBUTTON.....................................................8
Autorange........................................................8
® Manual Range................................................6
® Automatic Touch Hold Mode........................10
DIGITAL DISPLAY...............................................12
BAR
GRAPH.........................................................12
STANDBY..............................................................12
TAKING MEASUREMENTS...............................14
V Measuring Voltage.........................................14
Π Measuring Resistance...................................16
»DI Testing
Continuity...........................................17
-μ- Testing
Diodes...............................................18
A Testing
Current...............................................20
HOLSTER..............................................................22
MAINTENANCE....................................................23
Internal Fuse Test..........................................24
Replacing the Battery and Fuse(s)..............25
Service & Parts...............................................26
SPECIFICATIONS................................................28
SERVICE CENTERS...........................................34
Fluke-7716-Manual-Page-1-Picture
Start Free Download


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
What is the sum of 1 + 2 + 3?
Powered by Commentics