Equipment information:

Fluke 80E Voltage Source
Manufacturer:
Fluke
Model: 80E
Date: 1981
Category: Measurement instruments
Group: Voltage Source
Description: Voltage Divider
Information:
                                    The Model 80E Voltage Dividers extend the measuring range of
Fluke differential voltmeters. The Model 80E-10 has a
maximum input voltage of 10KV. The Model 80E-5 has a maximum
input voltage of 5KV. Other input voltages are available on
request. Both 10V and IV output terminals are provided,
which permit use of the 80E with Fluke differential
voltmeters, or a null- type potentiometer.
1-3. A center zero panel meter permits observation of the
approximate magnitude and polarity of the unknown voltage.
In order to ensure maximum accuracy and long life, properly
aged, wirewound resistors, having a very low temperature
coefficient, are used throughout the instrument. The case of
the instrument is suitable for either bench use or rack
mounting.
1-4. This instrument has been thoroughly checked and tested
before being shipped from the factory. Immediately after
receiving the instrument, carefully inspect for any damage
which may have occurred during transit. If any damage is
noted, refer to the instructions outlined in the back of
this manual.

These manuals are available for the above equipment:

Fluke -- 80E -- User Manual
File name: Fluke-7663-Manual-Page-1-Picture
Manual Type: User Manual
Pages: 31
Size: 1.89 Mbytes (1986486 Bytes)
Language: english
Revision:
Manual-ID/Number: 293860
Date: June 1981
Quality: Scanned document, all readable.
Upload date:
MD5: dbd47e3a5e116ad1456c8d60c078cb0b
ed2kID: 58c44fadc4ddd350c35d0fd9f4820db8
Downloads: 41 since 29 January 2016
Information:
I INTRODUCTION AND SPECIFICATIONS 1-1
1-1.
Introduction...........................................................
1-1
1-5.
Specifications.......................................................
1-1
1-6,
Electrical................................................................
1-1
1-7.
Mechanical...........................................................
II OPERATING INSTRUCTIONS 2-1
2-1. Operating Procedure
........................................... 2-1
III THEORY OF OPERATION 3-1
3-1. Theory of
Operation.......................................... 3-1
IV MAINTENANCE 4-1
4-1.
Introduction...........................................................
4-1
4-2.
Troubleshooting...................................................
4-1
4-5. Calibration of
8ÖE-10...................................... . 4-1
4-7. Calibration of
80E-5.......................................... 4-2
V LIST OF REPLACEABLE PARTS 5-1
5-1.
Introduction............................................................
5-1
5-2. How to Obtain
Parts.......................................... 5-1
5-3. Use Code
Effectivity.......................................... 5-5
Fluke-7663-Manual-Page-1-Picture
Start Free Download


Comments

No comments yet.

Add Comment

* Required information
(never displayed)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
What is the opposite word of small?
 
Enter answer:
 
Notify me of new comments via email.
 
Remember my form inputs on this computer.
 
 
Powered by Commentics