Equipment information:

Fluke 2620A/05 Other
Model: 2620A/05
Date: 2002
Category: Measurement instruments
Group: Other
Description: Data Acquisition Unit
                                    The 2620A Hydra Series II Data Acquisition Unit is a
multi-channel data acquisition unit able to measure ac and
dc voltages, temperature via thermocouples and RTDs,
resistance, and frequency. It features 21 measurement
channels, 8 digital input/output lines, a Totalizer input,
and 4 alarm output lines. The Data Acquisition Unit is
easily carried by hand and can be ac or dc powered. The user
can choose communications with a host computer over an
RS-232 (standard) or IEEE-488 (2620A/05) computer interface.

The 2620A comes with a removable Universal Input Module that
enables fast, convenient set-up and reconfiguration. Any
combination of dc voltage, ac voltage, thermocouple, RTD,
resistance, or frequency measurements can be connected to
the input module without the need for additional signal
conditioning. Thermocouple reference junction compensation
is automatically performed by sensing the temperature of the
input module's isothermal block.


    Channel Scanning: can be continuous scanning, scanning
at an interval time, single scans, or triggered (internal or
external) scans
    Channel Monitoring: make measurements on a single
channel and view these measurements on the display
    Channel Scanning and Monitoring: view measurements made
for the monitor channel while scanning of all active
channels continues
    Multi-Function Display: Left (numeric) display shows
measurement readings; also used when setting numeric
parameters; Right (alphanumeric) display used for numeric
entries, channel number selection and display, status
information, and operator prompts
    Front-Panel Operation
    Measurement Input Function and Range:
     Volts dc (Vdc), dc voltage ranges 300 mV, 3 V, 30 V, 300 V
     Volts ac (Vac), ac voltage ranges 300 mV, 3 V, 30 V, 300 V
     Frequency (Hz), 15 Hz to 1 MHz
     Resistance (Ω), resistance ranges: 300 Ω, 3 kΩ, 30 kΩ,
300 kΩ, 3 MΩ, 10 MΩ
    Temperature Measurement: Thermocouple types J, K, E, T,
N, R, S, and B, and Hoskins Engineering Co. type C are
supported. Also, DIN/IEC 751 Platinum RTDs are supported
    Totalize Events on the Totalizing Input
    Alarm Limits and Digital Output Alarm Indication
    4-Terminal Resistance Measurements (Channels 1 through
10 only)
    RS-232 Computer Interface Operation
    Measurement Rate Selection
    Nonvolatile Memory: Storage of minimum, maximum, and
most recent measurements for all scanned channels. Storage
of Computer Interface setup, channel configurations, and
calibration values.
    RS-232 interface (IEEE-488 available with option 05)
    90 to 264 Vac, 50 or 60 Hz operation; or 9.0 to 16 Vdc
    Weight: 7 lb; Size: 93 mm (3.67 in)H x 216 mm (8.5 in)W
x 312 mm (12.3 in)D

These manuals are available for the above equipment:

Fluke -- 2620A/05 -- Datasheet
File name: Fluke-6511-Manual-Page-1-Picture
Manual Type: Datasheet
Pages: 12
Size: 186.46 Kbytes (190940 Bytes)
Language: english
Revision: C
Manual-ID/Number: 1264012
Date: March 2002
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 46237362669f2b7f0620eacb4636484d
ed2kID: 1a6e33a7ad87de5abb322241d32ec0b0
Downloads: 96 since 29 November 2014
Start Free Download


No comments yet.

Add Comment

* Required information
(never displayed)
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
Enter the word shark backwards.
Enter answer:
Notify me of new comments via email.
Remember my form inputs on this computer.
Powered by Commentics