Equipment information:

Taylor Electrical Instruments Windsor Model 66A Generator
Manufacturer:
Taylor Electrical Instruments
Model: Windsor Model 66A
Date:
Category: Measurement instruments
Group: Generator
Description: R.F. Signal generator
Information:
                                    This instrument is a general purpose R.F. Signal Generator
of advanced design. It covers a very wide frequency range
and is suitable for professional work on both radio and
television receivers. Special attention has been paid to
attenuation, and the unwanted external radiation is
extremely low, due to the efficient double screening and
careful filtration.
The R.F. oscillator uses a triode in a Hartley circuit on
the first 5 ranges but on the 6th range this becomes a
Colpitts oscillator. Low impedance pickup coils are loosely
coupled to the oscillator coils. Owing to the loose coupling
and the fact that these coils are separately switched there
is negligible frequency shift when the attenuator setting is
altered. Modulation at 400 cycles to a depth of 30 per cent,
is effected by another triode Hartley oscillator.

These manuals are available for the above equipment:

Taylor Electrical Instruments -- Windsor Model 66A -- Service and User Manual
File name: Taylor-6082-Manual-Page-1-Picture
Manual Type: Service and User Manual
Pages: 11
Size: 350.91 Kbytes (359328 Bytes)
Language: english
Revision:
Manual-ID/Number:
Date:
Quality: Scanned document, all readable.
Upload date:
MD5: 6eb8bcd10fa6433cb5ad43f2b48a0a98
ed2kID: a5a354a97bdd85fccedc52b78fa4bcac
Downloads: 103 since 25 May 2014
Information:
CIRCUIT DIAGRAM
....................................................
............... 2
1. DESCRIPTION.
1/1. General ... ... ... ............... ... ... 4
1/2. Controls ... ........................................
............... 4
1/3. Frequency Ranges ...............
........................................4
1/4. Terminating Unit ... ... ... ... ... ... 5
1/5. Output Voltage ... ... ... ... ... ... 5
2. OPERATION.
2/1. Mains Adjustment ... ... ............... ... ... 5
2/2. Connection to Receiver ... ... ... ... ... 6
,p-
3. APPLICATIONS.
3/1. General ............... ... ... ... ... ... 7
3/2. Alignment and Ganging ... ... ... ... ... 7
3/3. Sensitivity Measurements ... ... ............... ... 8
3/4. Selectivity Measurements ... ... ... ............... 8
4. SERVICE.
4/1. Valve Replacement ... ... ... ... , ............... 9
APPENDIX—Wavelength/Frequency Conversion Chart ...............10
GUARANTEE
..........................................................................................11
Taylor-6082-Manual-Page-1-Picture
Start Free Download


Comments

No comments yet.

Add Comment

* Required information
(never displayed)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
What is the fifth month of the year?
 
Enter answer:
 
Notify me of new comments via email.
 
Remember my form inputs on this computer.
 
 
Powered by Commentics