Equipment information:

Anritsu MS4662A Network Analyzer
Manufacturer:
Anritsu
Model: MS4662A
Date: 1988
Category: Measurement instruments
Group: Network Analyzer
Description:
Information:
                                    The MS4661A/E include a built-in transmission/reflection
measurement
test set (bridge), making them ideal for measuring antennas and
passive devices (filters, attenuators, switches, cables)
where the input
and output impedances are nearly equal. The MS4662A also has an
S-parameter test set. In addition to measuring active
devices with different
input and output characteristics (such as amplifiers), it
measures
forward and reverse direction characteristics with a single
connection.
You can choose the model best suited to your application.
The MS4661A and MS4662A has color LCD displays, while the
MS4661E has an EL display (monochrome).
The high-speed synthesizer and DSP (digital signal
processor) permit
measurements at 400 μs/point (or 600 μs/point using two-port
calibration),
with sweep times approximating real-time measurement.
Post-measurement data analysis is facilitated by unique
functions
such as limit tests, 3 dB bandwidth searches, and ripple
searches for
device evaluation and pass/fail identification. With PTA
(Personal Test
Automation) capability as standard, it is easy to configure ATE
(Automated Test Equipment) systems.
Features
• Built-in transmission/reflection measurement, and
S-parameter test set
• Full range of limit test functions for real-time pass/fail
testing
• One-touch measurement of each characteristic using target data
search function
• Time domain analysis

These manuals are available for the above equipment:

Anritsu -- MS4662A -- Datasheet
File name: Anritsu-5911-Manual-Page-1-Picture
Manual Type: Datasheet
Pages: 5
Size: 205.09 Kbytes (210008 Bytes)
Language: english
Revision:
Manual-ID/Number:
Date:
Quality: Electronic document, no scan, very well readable.
Upload date:
MD5: 48a8b2dc96d3e589274dc938f5bb4e0e
ed2kID: 0f8c88fdb8c9cd18464828a4a82eb641
Downloads: 111 since 02 May 2014
Information:
Anritsu-5911-Manual-Page-1-Picture
Start Free Download


Anritsu -- MS4662A -- User Manual
File name: Anritsu-5912-Manual-Page-1-Picture
Manual Type: User Manual
Pages: 396
Size: 4.99 Mbytes (5230226 Bytes)
Language: english
Revision: Fourth Edition
Manual-ID/Number: M-W0997AE-4.0
Date: March 1997
Quality: Scanned document, all readable.
Upload date:
MD5: 5a3f176955c2f041f1b599195b261ca4
ed2kID: 5908fb1b2c64ee0f1726181a92244d54
Downloads: 66 since 02 May 2014
Information:
Operation Manual Volume 1
Panel Operations

This manual is divided into 12 chapters and three
appendixes. A brief description of each of the chapters is
given below.
Chapter	Description
Chapter 1 General	Product overview, organization of
documentation, standard analyzer configuration, options,
application components and peripherals, and standards.
Chapter 2 Preparations	Preparations to be completed before
starting to use (turning on) the unit.
Chapter 3 Basic  Operating  Instructions	Basic operating
instructions for first-time users of the MS4662A.
Chapter 4 Selecting  Methods of Displaying Measurement Data
Methods of selecting data types for measurement data and the
corresponding graph formats, and displaying the graphs at
optimal positions on screen, and marker function.
Chapter 5 Selecting  Measurement  Parameters	Selecting
measurement parameters with the FREQ, SWEEP, PORT POWER, and
AVG keys in the MEASURE section.
Chapter 6 Package Functions	Functions designed to simplify
the workflow of measurement, such as displaying titles,
setting dates and times, changing measurement points, and
isolating and calculating characteristic points in traced
waveforms.
Chapter 7 Limit Testing Function	Evaluation of measurement
results as PASS or FAIL.
Chapter 8 Hard-Copying and Save/Recall Functions	Copy
function that hard-copies display images to printers or
plotters, and PMC file save/recall functions.
Chapter 9 Calibrating  Measurement  Values	Explanations of
the methods of calibrating measurement values, and practical
examples (X-S method, single-port OSL method, two-port OSL
method, and single-path two-port method).
Chapter 10 Testing	Typical examples of S-parameter and
time-domain measurement.
Chapter 11 Unit  Performance  Testing	Instruments and
apparatus needed to executed MS4662A performance testing,
their setup, and performance testing procedures
Chapter 12 Storage and  Transportation	Daily care, long-term
storage, and repacking and transportation
Appendixes AtoC	Appendix C contains foldout front and rear
panel views at the end of the VOLUME.  Open the foldouts to
read this manual while observing the uanel
	operator side.
Anritsu-5912-Manual-Page-1-Picture
Start Free Download


Anritsu -- MS4662A -- User Manual
File name: Anritsu-5913-Manual-Page-1-Picture
Manual Type: User Manual
Pages: 196
Size: 1.70 Mbytes (1781809 Bytes)
Language: english
Revision: Fourth Edition
Manual-ID/Number: M-W0998AE-4.0
Date: March 1997
Quality: Scanned document, all readable.
Upload date:
MD5: 1dc322aaaf7357625775ea669fb3e72c
ed2kID: d42165ad56738413ac997a428f00fc21
Downloads: 97 since 02 May 2014
Information:
Operation Manual Volume 2
GPIB Remote Control

Anritsu-5913-Manual-Page-1-Picture
Start Free Download


Comments

No comments yet.

Add Comment

* Required information
(never displayed)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Is it true or false that green is a number?
 
Enter answer:
 
Notify me of new comments via email.
 
Remember my form inputs on this computer.
 
 
Powered by Commentics