Equipment information:

Systron Donner TL8-3 Series Power supply
Manufacturer:
Systron Donner
Model: TL8-3 Series
Date: 1973
Category: Measurement instruments
Group: Power supply
Description: Triple Power Supply
Information:
                                    The TLB-3 Triple Output Lab power supply is a multiple
output unit specifically designed for laboratory applications
utilizing IC circuitry. Independent output voltages are
provided to allow simultaneous power to be supplied to
a typical IC (digital or analog) breadbord circuit, as well as
simultaneously, two additional independent power sources
for typical auxiliary circuitry. Output voltage and currents
may be independently monitored
A variety of voltage and current outputs are available
providing unexcelled operational versatility and flexibility.
This output flexibility permits the user to have complete
convenience in filling laboratory power requirements.
The Triple Lab Power Supply utilizes silicon semiconductors
permitting operation at its maximum temperature
rating without derating.

Operation Mode: Constant voltage with automatic current
limiting.
Controls:
Voltage: Coarse and Fine ; 0 to rated output; front panel.
Resolution
1 mV on fine control.
Input Power: Front panel switch and indicator, AC ON.
Metering: (3) Combination Volt/Ammeters with front panel
selector switch.
Terminals:
Front Panel: Positive output A, Positive output B, Negative
output C, common return, chassis ground.
Overvoltage Protection: Internal adjustable overvoltage
protection
is available, as a factory option on output A (0 to + 8 VDC)
Size: 77/a" W x 47/a" H x 12e/1e" D
Weight: 16 lbs.

These manuals are available for the above equipment:

Systron Donner -- TL8-3 Series -- Service and User Manual
File name: SystronDonner-5464-Manual-Page-1-Picture
Manual Type: Service and User Manual
Pages: 30
Size: 8.19 Mbytes (8587982 Bytes)
Language: english
Revision:
Manual-ID/Number:
Date: 1973
Quality: Scanned document, all readable.
Upload date:
MD5: 3217cf6f47e4b91ab2b4fb9ec3d42ad4
ed2kID: 4f65fcb8edf6dbb85862ddae175800dd
Downloads: 167 since 09 February 2014
Information:

1.1 Introduction ...... .............. .... .... .
1.2 General Features .. .. . ... . . . . . . .. . .... ... .
1.3 Precautionary Measures .. . .. . . . .. . .. . .. . . .
1.4 Specification Data Sheet . .... .. .. . ...... .
OPERATION
2.1 Electrical Connections ...... . ........... .
2.2 Controls .. . . .. ............ .. . ... . . . ..... .
2. 3 Operation .. . ...... .. .......... . ... . .. ... .
THEORY OF OPERATION
3. 1 Genera 1 . .... .............. .. . . ... . . . ... . .
3.2 Optional Features .. ...... .. .... ........ ..
3.3 Block Dfagram . . . . . . .... . .... ......... .. . .
MAINTENANCE
4. 1 Genera 1 . . .•.•• . •• •...• . . • . . •.•..•...•.•.•
4.2 loads and Interconnections ......... . .... .
4.3 Troubleshooting .. . ..... . ... . . . ... . . .... . .
CALIBRATION
5. 1 Genera 1 •..• .• .• • . ••..•• . ••.. ..•.•... . .••.
5.2 Test Equipment Required . ..... ... . ... . .. . .
5.3 Calibration Procedure . . . .. . ............. .
SystronDonner-5464-Manual-Page-1-Picture
Start Free Download


Comments (2)

Topic: Systron Donner TL8-3 Series
Sort
0/5 (0)
Facebookdel.icio.usStumbleUponDiggTechnoratiGoogle+RedditMySpaceTwitterLinkedIn
Gravatar
Robert says...
Hi, For some reason, I'm only getting a 0 bit file...
Is this manual still available?
It's for the Systron Donner TL8-3 power supply.
Thanks!
27th February 2015 3:23am
Gravatar
Oliver says...
Hi Robert
Thanks for your comment. I had a error in my filesystem.
Now the download should work correct.

Oliver
28th February 2015 12:07am
Page 1 of 1

Add Comment

* Required information
(never displayed)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Enter the word shark backwards.
 
Enter answer:
 
Notify me of new comments via email.
 
Remember my form inputs on this computer.
 
 
Powered by Commentics