Equipment information

Systron Donner TL8-3 Series Power supply
Manufacturer
Systron Donner
Model TL8-3 Series
Date 1973
Category: Measurement instruments
Group Power supply
Description Triple Power Supply
Information
                                    The TLB-3 Triple Output Lab power supply is a multiple
output unit specifically designed for laboratory applications
utilizing IC circuitry. Independent output voltages are
provided to allow simultaneous power to be supplied to
a typical IC (digital or analog) breadbord circuit, as well as
simultaneously, two additional independent power sources
for typical auxiliary circuitry. Output voltage and currents
may be independently monitored
A variety of voltage and current outputs are available
providing unexcelled operational versatility and flexibility.
This output flexibility permits the user to have complete
convenience in filling laboratory power requirements.
The Triple Lab Power Supply utilizes silicon semiconductors
permitting operation at its maximum temperature
rating without derating.

Operation Mode: Constant voltage with automatic current
limiting.
Controls:
Voltage: Coarse and Fine ; 0 to rated output; front panel.
Resolution
1 mV on fine control.
Input Power: Front panel switch and indicator, AC ON.
Metering: (3) Combination Volt/Ammeters with front panel
selector switch.
Terminals:
Front Panel: Positive output A, Positive output B, Negative
output C, common return, chassis ground.
Overvoltage Protection: Internal adjustable overvoltage
protection
is available, as a factory option on output A (0 to + 8 VDC)
Size: 77/a" W x 47/a" H x 12e/1e" D
Weight: 16 lbs.

These manuals are available for the above equipment:

Systron Donner -- TL8-3 Series -- Service and User Manual
File name SystronDonner-5464-Manual-Page-1-Picture
Manual Type Service and User Manual
Pages 30
Size 8.19 Mbytes (8587982 Bytes)
Language english
Revision
Manual-ID/Number
Date 1973
Quality Scanned document, all readable.
Upload date
MD5 3217cf6f47e4b91ab2b4fb9ec3d42ad4
Downloads 579 since 09 February 2014
Information

1.1 Introduction ...... .............. .... .... .
1.2 General Features .. .. . ... . . . . . . .. . .... ... .
1.3 Precautionary Measures .. . .. . . . .. . .. . .. . . .
1.4 Specification Data Sheet . .... .. .. . ...... .
OPERATION
2.1 Electrical Connections ...... . ........... .
2.2 Controls .. . . .. ............ .. . ... . . . ..... .
2. 3 Operation .. . ...... .. .......... . ... . .. ... .
THEORY OF OPERATION
3. 1 Genera 1 . .... .............. .. . . ... . . . ... . .
3.2 Optional Features .. ...... .. .... ........ ..
3.3 Block Dfagram . . . . . . .... . .... ......... .. . .
MAINTENANCE
4. 1 Genera 1 . . .•.•• . •• •...• . . • . . •.•..•...•.•.•
4.2 loads and Interconnections ......... . .... .
4.3 Troubleshooting .. . ..... . ... . . . ... . . .... . .
CALIBRATION
5. 1 Genera 1 •..• .• .• • . ••..•• . ••.. ..•.•... . .••.
5.2 Test Equipment Required . ..... ... . ... . .. . .
5.3 Calibration Procedure . . . .. . ............. .
SystronDonner-5464-Manual-Page-1-Picture
Start Free Download


Comments (1)

 
 
Topic: Systron Donner TL8-3 Series
0/5 (0)
 
Gravatar
New
Robert
Gravatar
3
0
0
Dec 2014
First Poster
Robert says...
Hi, For some reason, I'm only getting a 0 bit file...
Is this manual still available?
It's for the Systron Donner TL8-3 power supply.
Thanks!
Gravatar
Regular
Oliver
Gravatar
44
0
0
Oct 2013
Top Poster
Oliver says...
Hi Robert
Thanks for your comment. I had a error in my filesystem.
Now the download should work correct.

Oliver

Add Comment

* Required information
1000
What is the opposite word of weak?
Powered by Commentics