Fluke 8050A Digital multimeter
Manufacturer:
Image 1 of 3
Image 2 of 3
Image 3 of 3
If you have any other photos or manuals for the
Fluke 8050A you can upload the files here .
Model:
8050A
Date:
1979
Category:
Group:
Description:
portable bench- type digital multimeter
Information
1-2. Your John Fluke Model 8050A is a portable bench-
type Digital multimeter (DMM) with a 4-1 /2 digit liquid
crystal display (LCD). The 8050A has all the following
industry-standard features:
» Voltage measurements from 10 μ to 1000V dcand 10 mV to
750V true-rms ac.
• Current measurements from 10 nA to 2A dc and 10 μΑ to 2A
true-rms ac.
® Resistance measurements from 10 mH to 20ΜΏ.
The 8050A also has several special measurement features.
These special features include the following:
• Conductance measurements up to 100,000 Mil.
• Voltage measurements in decibels, that can be referenced
to 1 of 16 user selected reference impedances.
® Resistance ranges that supply enough voltage to turn on a
PN junction to allow diodes and transistors to be tested.
• The ability to store any input signal as an offset or
relative reference value.
• Automatic polarity indication and overrange indication.
• Protection from overloads and protection from transients
of up to 6 kV, 10 microseconds.
• Dual-slope integration a/d conversion to ensure noise-free
measurements.
• Long term calibration stability (1 year).
1-3. The 8050A is warranted for a period of one year upon
shipment of the instrument to the original purchaser.
Conditions of the warranty are given at the front of this
manual. The 8050A is typically powered from ac line voltages
but may be powered by the optional rechargeable battery.
Manual type:
Service and User Manual
Pages:
106
Size:
5.11 Mbytes (5360134 Bytes)
Language:
english
Revision:
2
Manual ID:
530907
Date:
Quality:
Scanned document, all readable.
Upload date:
2016 02 13
MD5:
645b1f5f0f6c33dddc5fe37e20c5466f
Downloads:
1914
Information
1
2
TITLE PAGE
INTRODUCTION AND SPECIFICATIONS
... 1-1
l-l. INTRODUCTION .
I-4. OPTIONS AND ACCESi
I-5. SPECIFICATIONS
...
1-1
SORIES ...
1-1
...
1-1
OPERATION
...
2-1
2-1. INTRODUCTION
...
2-1
2-3. SETTING UP YOUR INSTRUMENT
... 2-1
2-4. Unpacking
...
2-1
2-8. AC Line Voltage Requirements
...
2-1
2-10. Fuse
Replacement ...
2-1
2-13. FRONT PANEL
FEATURES ...
2-2
2-15. Display
...
2-2
2-18. SIGNAL INPUT LIMITS
...
2-2
2-20. OPERATING
TECHNIQUES ...
2-3
2-22. AC/DC Voltage (V)
...
2-3
2-24. AC/DC Current (mA)
...
2-3
2-26. Resistance (Ω)
...
2-7
2-28. Conductance (S =
IΩ) ...
2-7
2-30. Diode Test
...
2-7
2-32. Relative (RELATIVE)
...
2-7
2-36. Decibel
(dB) ...
2-11
2-38. INITIAL CHECKOUT PROCEDURE
... 2-12
2-41. APPLICATIONS
...
2-12
2-43. DC Voltage Measurement
... , ...
2-12
2-51. Current Measurement
...
2-13
2-56. Resistance Measurement
...
2-13
2-62. Conductance Measurement
...
2-14
2-80. Relative Measurement
...
2-16
2-84. AC Voltage and Current
Measurement ... 2-16
THEORY OF
OPERATION ...
3-1
3-1. INTRODUCTION
...
3-1
3-3. FUNCTIONAL DESCRIPTION
... 3-1
3-5. CIRCUIT
DESCRIPTION ...
3-1
TITLE PAGE
3-7. A/D Converter
... 3-1
3-18. Microcomputer
... 3-2
3-20. Signal Conditioning
... 3-6
3-31. True-RMS Converter
... 3-8
3-38. Touch-Hold Circuit
... 3-8
3-40, Voltage Protection
... 3-8
3-43. Current Protection
... 3-8
4 MAINTENANCE
...
4-1
4-1. INTRODUCTION
...
4-1
4-4. SERVICE INFORMATION
...
4-1
4-7. GENERAL INFORMATION
...
4-1
4-9. Interior
Access ...
4-1
4-24. dB Reference Impedance Power-Up
Setting ... 4-4
4-26. Cleaning
...
4-5
4-28. PERFORMANCE TESTS
...
4-5
4-30. Initial Procedures
...
4-5
4-32. Display
Test ...
4-5
4-34. Linear Voltage Test
... * ...
4-6
4-36. dB Voltage
Test ...
4-6
4-38. Current
Test ...
4-7
4-40. Resistance and Conductance Tests
... 4-7
4-42. CALIBRATION ADJUSTMENTS
... 4-8
4-44. DC Calibration ...
... 4-8
4-46. AC Calibration ...
... 4-8
4-48. Jumper
Selection ...
4-8
4-57. TROUBLESHOOTING
...
4-12
5 LIST OF REPLACEABLE PARTS
...
5-1
TABLE OF CONTENTS
...
5-1
5-1. INTRODUCTION
...
5-2
5-3. PARTS ORDERING INFORMATION
... 5-2
6 OPTIONS AND Accessories
...
6-1
TABLE OF CONTENTS
...
6-1
INTRODUCTION
...
6-2
ACCESSORIES
...
600-1
OPTIONS
...
601-1
7 SCHEMATIC DIAGRAMS
...
7-1
TABLE OF CONTENTS
...
7-1
APPENDIX A
...
A-1
Manual type:
User Manual with schematics
Pages:
97
Size:
2.95 Mbytes (3088117 Bytes)
Language:
english
Revision:
2 7/84
Manual ID:
530907
Date:
Quality:
Scanned document, all readable.
Upload date:
2009 02 19
MD5:
8c0a3ade3a5172d52d90ef6687562db8
Downloads:
3498
Manual type:
Service and User Manual
Pages:
104
Size:
8.51 Mbytes (8920364 Bytes)
Language:
english
Revision:
2
Manual ID:
530907
Date:
Quality:
Scanned document, all readable.
Upload date:
2016 01 27
MD5:
9046d8988f512b66553942430b1b1d33
Downloads:
932
Information
1 INTRODUCTION AND SPECIFICATIONS 1-1
1-1. INTRODUCTION 1-1
1-4. OPTIONS AND Accessories 1-1
1-5. SPECIFICATIONS
...
1-1
2 OPERATION
...
2-1
2-1. INTRODUCTION
...
2-1
2-3. SETTING UP YOUR INSTRUMENT ... 2-1
2-4. Unpacking
...
2-1
2-8. AC Line Voltage Requirements 2-1
2-10. Fuse Replacement 2-1
2-13. FRONT PANEL FEATURES 2-2
2-15. Display 2-2
2-18. SIGNAL INPUT LIMITS 2-2
2-20. OPERATING TECHNIQUES 2-3
2-22. AC/DC Voltage (V) 2-3
2-24. AC/ DC Current (mA) 2-3
2-26. Resistance (Ω) 2-7
2-28. Conductance (S = 1Ω) 2-7
2-30. Diode Test 2-7
2-32. Relative (RELATIVE) 2-7
2-36. Decibel (dB) 2-11
2-38. INITIAL CHECKOUT PROCEDURE ... 2-12
2-41. APPLICATIONS 2-12
2-43. DC Voltage Measurement 2-12
2-51. Current Measurement 2-13
2-56. Resistance Measurement 2-13
2-62. Conductance Measurement 2-14
2-80. Relative Measurement 2-16
2-84. AC Voltage and Current
Measurement ... 2-16
3 THEORY OF
OPERATION ...
3-1
3-1. INTRODUCTION
...
3-1
3-3. FUNCTIONAL DESCRIPTION 3-1
TITLE PAGE
3-7. A/D Converter
... 3-1
3-18. Microcomputer
... 3-2
3-20. Signal Conditioning
... 3-6
3-31. True-RMS
Converter ... 3-8
3-38. Touch-Hold Circuit
... 3-8
3-40. Voltage Protection
... 3-8
3-43. Current Protection
... 3-8
4 MAINTENANCE
...
4-1
4-1. INTRODUCTION
...
4-1
4-4. SERVICE INFORMATION
...
4-1
4-7. GENERAL INFORMATION
...
4-1
4-9. Interior
Access ...
4-1
4-24. dB Reference Impedance Power-Up
Setting ... 4-4
4-26. Cleaning
...
4-5
4-28. PERFORMANCE TESTS
...
4-5
4-30. Initial Procedures
...
4-5
4-32. Display
Test ...
4-5
4-34. Linear Voltage Test
...
4-6
4-36. dB Voltage
Test ...
4-6
4-38. Current
Test ...
4-7
4-40. Resistance and Conductance
Tests ... 4-7
4-42. CALIBRATION ADJUSTMENTS
... 4-8
4-44. DC Calibration
...
4-8
4-46. AC Calibration
...
4-8
4-48. Jumper
Selection ...
4-8
4-57. TROUBLESHOOTING
...
4-12
5 LIST OF REPLACEABLE PARTS
...
5-1
TABLE OF CONTENTS
...
5-1
5-1. INTRODUCTION
...
5-2
5-3. PARTS ORDERING INFORMATION
... 5-2
6 OPTIONS AND Accessories
...
6-1
TABLE OF CONTENTS
...
6-1
INTRODUCTION
...
6-2
ACCESSORIES
...
600-1
OPTIONS
...
601-1
7 SCHEMATIC DIAGRAMS
...
7-1
TABLE OF CONTENTS
...
7-1
APPENDIX A
...
A-1