Geräte Informationen:

Thurlby Thandar Instruments TTI TG2000 Generator
Hersteller:
Thurlby Thandar Instruments TTI
Modell: TG2000
Datum: 2010
Kategorie: Messgeräte
Gruppe: Generator
Beschreibung: DDS Function Generator
Informationen:
                                    This Programmable Function Generator uses direct digital
synthesis to provide high performance and extensive
facilities at a breakthrough price. It can generate a
variety of waveforms between 1mHz and 20MHz with a
resolution of 6 digits and an accuracy better than 10ppm.
Direct digital synthesis for accuracy & stability
Direct digital synthesis (DDS) is a technique for generating
waveforms digitally using a phase accumulator, a look-up
table and a DAC. The accuracy and stability of the resulting
waveforms is related to that of the crystal master clock.
The DDS generator offers not only exceptional accuracy and
stability but also high spectral purity, low phase noise and
excellent frequency agility.
A wide range of waveforms
High quality sine, square and pulse waveforms can be
generated over the full frequency range of 1mHz to 20MHz.
Triangle waveforms can also be generated but with
limitations as to the maximum useable frequency.
Variable symmetry/duty-cycle is available for squarewave and
pulse waveforms.
Sweep
All waveforms can be swept from 0.2Hz to their maximum
frequency in a single sweep at a rate variable between 50
milliseconds and 999 seconds. The sweep is fully phase
continuous.
Sweep can be linear or logarithmic, single or continuous.
Single sweeps can be triggered from the front panel, the
trigger input, or the digital interfaces. A sweep marker is
provided.
AM
External Amplitude Modulation is available for all waveforms.
FSK and Tone modes
Frequency Shift Keying provides phase coherent switching
between two selected frequencies; in Tone mode the output is
stepped asynchronously through a user-defined list of up to
16 frequencies. In both modes the switching source can be
the internal trigger generator, front panel, an external
signal or a remote command.
Easy and convenient to use
All of the main generator parameters are clearly displayed
together on a backlit LCD with 4 rows of 20 characters. Sub
menus are used to set the parameters for each function.
All parameters can be entered directly from the numeric
keypad. Alternatively most parameters can be incremented or
decremented using the rotary encoder.
This system combines quick and easy numeric data entry with
quasi-analogue adjustment when required.
Fully programmable via USB and Addressable RS-232
The generator has both USB and RS-232 interfaces which can
be used for remote control of all of the instrument functions.
As well as operating in conventional single instrument mode
the RS-232 serial interface can also be used in addressable
mode whereby up to 32 instruments can be linked to a single
PC serial port.

Folgende Anleitungen sind für obiges Gerät verfügbar:

Thurlby Thandar Instruments TTI -- TG2000 -- Bedienungsanleitung
Dateiname: Thurlby-4728-Manual-Page-1-Picture
Dokumenttyp: Bedienungsanleitung
Seitenanzahl: 46
Dateigröße: 1.12 Mbytes (1179567 Bytes)
Sprache: Englisch
Revision: Issue 6
Dokument-ID/Nummer: 48591-1020
Datum: 2010
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: f2fc98beedd0dfa5a174082d550845d0
ed2kID: c83a5d22af68e468b9fdc36132e78ae1
Downloads: 168 seit 02 November 2013
Informationen:
Introduction 2
Specifications 3
Safety 6
EMC 8
Installation 9
Connections 10
Front Panel Connections 10
Rear Panel Connections 11
General 12
Initial Operation 12
Standard Waveform Operation 15
Setting Generator Parameters 15
AUX Output 18
Warnings and Error Messages 19
Sweep Operation 20
General 20
Setting Sweep Parameters 20
Gated Mode 25
Tone Mode 26
FSK 27
Modulation 28
System Operations from the Utility Menu 29
Calibration 31
Equipment Required 31
Calibration Procedure 31
Calibration Routine 32
Remote Calibration 33
Remote Operation 34
USB Interface 38
Remote Commands 39
Maintenance 42
Appendix 1. Warning and Error Messages 43
Appendix 2. Factory System Defaults 44
Thurlby-4728-Manual-Page-1-Picture
Kostenlos herunterladen


Thurlby Thandar Instruments TTI -- TG2000 -- Bedienungsanleitung
Dateiname: Thurlby-8405-Manual-Page-1-Picture
Dokumenttyp: Bedienungsanleitung
Seitenanzahl: 46
Dateigröße: 981.81 Kbytes (1005377 Bytes)
Sprache: Englisch
Revision: Issue 5
Dokument-ID/Nummer: 48591-1020
Datum:
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: cc6a5f598604b289f2119a09a49f500d
ed2kID: 8758e19baf34441a522ba3d555e28fbc
Downloads: 8 seit 14 Januar 2017
Informationen:
Introduction 2
Specifications 3
Safety 6
EMC 8
Installation 9
Connections 10
Front Panel Connections 10
Rear Panel Connections 11
General 12
Initial Operation 12
Standard Waveform Operation 15
Setting Generator Parameters 15
AUX Output 18
Warnings and Error Messages 19
Sweep Operation 20
General 20
Setting Sweep Parameters 20
Gated Mode 25
Tone Mode 26
FSK 27
Modulation 28
System Operations from the Utility Menu 29
Calibration 31
Equipment Required 31
Calibration Procedure 31
Calibration Routine 32
Remote Calibration 33
Remote Operation 34
USB Interface 38
Remote Commands 39
Maintenance 42
Appendix 1. Warning and Error Messages 43
Appendix 2. Factory System Defaults 44
Thurlby-8405-Manual-Page-1-Picture
Kostenlos herunterladen


Kommentare

Noch keine Kommentare vorhanden.

Kommentar Hinzufügen

* Pflichtfeld
(wird nicht veröffentlicht)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Enter the last letter of the word satellite.
 
Die Antwort lautet:
 
Informiere mich via E-Mail über neue Kommentare.
 
Meine Daten auf diesem Computer.
 
 
Powered by Commentics