Geräte Informationen:

Hickok Electrical Instrument Company 3310 Digital Multimeter
Hersteller:
Hickok Electrical Instrument Company
Modell: 3310
Datum: 1971
Kategorie: Messgeräte
Gruppe: Digital Multimeter
Beschreibung:
Informationen:
                                    The Model 3310 Universal Digital Multimeter has 32 ranges
covering ac volts and ac current, dc volts and dc current,
resistance, and direct reading true rms dBm at lmW/600
n or 1 mW/900i2 reference. The multimeter may be operated
from a 115 or 230 volt * ac line or from an internal
rechargeable battery pack (The rechargeable nickel cadmium
battery pack is optional). The batteries permit measurement
with complete isolation from power line interference
(infinite common mode rejection). Battery life is 20 hours
on all functions except ac volts, ac current and dBm
where life is minimum of 8 hours. The battery operated
version may be operated from the ac power line while
the batteries are being recharged. Charging circuits are
internal to the multimeter.

The bright fluorescent digital display consists of
seven-segment numerical indicators which provide a maximum
display of 1999. The display features include non-blinking
buffered readout, automatic polarity indicator, automatically
positioned decimal point and blinking overrange indication.
The reading rate is twice per second. The blinking over
range indication occurs when the reading exceeds 1999.

Operator convenience and safety have been stressed in
the design of the Model 3310. The equipment case consists
of box-in-box construction with outer case connected
to third wire ground. The input terminals and internal
circuitry may be elevated 1500 volts from line ground
without damage to the instrument. A color coded front
panel is provided for ease in selection of the 32 ranges.
High input impedance, guarded circuitry and true rms conversion
minimize erroneous measurements. The direct reading dBm
ranges provide conversion free dBm (1 mW/600i2 or 1 mW/900 n)
measurements over a 110 dB range.

Rugged construction, wide temperature operating range,
exceptional overload specifications, and operator convenience
make the Model 3310 ideal for laboratory, production
line or field applications.

Folgende Anleitungen sind für obiges Gerät verfügbar:

Hickok Electrical Instrument Company -- 3310 -- Serviceanleitung
Dateiname: Hickok-3866-Manual-Page-1-Picture
Dokumenttyp: Serviceanleitung
Seitenanzahl: 57
Dateigröße: 13.49 Mbytes (14143118 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: 2490-635
Datum: 1971
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: b9ed06657b29c6adac506eff73d0d5a3
ed2kID: 1aaf8f1e8b3a01a536acc03fc4df16f9
Downloads: 114 seit 07 Januar 2013
Informationen:
I	GENERAL INFORMATION .......................1-1

II	SPECIFICATIONS........................................................2-1

III	OPERATING INSTRUCTIONS..........................................3-1

Battery Operation..................................................3-1

AC Operation........................................................3-1

Front Panel..........................................................3-2

Measurements ......................................................3-2

DC Volts........................................................3-2

AC Volts........................................................3-2

Ohms ............................................................3-2

DC Current ....................................................3-3

AC Current ....................................................3-3

Guard............................................................3-3

dBm..............................................................3-3

IV	MINIMIZING EXTERNAL SOURCES OF ERROR................4-1

Loading Errors - AC..............................................4-1

AC Interference on DC Measurements........................4-1

Dielectric Absorption..............................................4-1

Loading Errors - DC ..........................................4-1

Environment..........................................................4-1

Ohms Measurements..............................................4-1

AC Distortion........................................................4-2

V	THEORY OF OPERATION..............................................5-1

VI	CIRCUIT DESCRIPTION................................................6-1

VII	FUNCTIONAL OPERATION............................................7-1

Positive DC Volts..................................................7-1

Negative DC Volts..................................................7-3

Ohms Operation ....................................................7-3

Megohms Operation................................................7-4

AC Volts and Current Operation................................7-6

DC Current Operation ............................................7-7

dBm ...................................................................7-7

VIII	TROUBLESHOOTING....................................................8-1

Recommended Equipment........................................8-1

Troubleshooting ....................................................8-1

1.	MOS-IC Outputs and Display ......................8-1

2.	Integrator Check........................................8-2

3.	Comparator Check......................................8-2

4.	Input and Self-zero Switching........................8-2

5.	Reference FET Switching

and Flip-Flop (Megohms Operation) ....	8-3

6.	Output Circuitry and YN..............................8-3

7.	Function and Range Switching ......................8-3

8.	DC Voltage Regulators..........................8-3

9.	Reset and Latch Toggle ......................8-4

10.	Reference Supply........................................8-4

11.	Power Supply............................................8-4

12.	AC/DC Converter......................................8-4

12.1.	RMS Converter..........................................8-4

12.2.	Log Converter (dBm)..................................8-5
IX	CALIBRATION............................................................9-1

Cleaning Procedure................................................9-1

Recommended Calibration Equipment........................9-1

Calibration Procedure............................................9-1

1.	Voltage Regulator......................................9-1

2.	Zero and Ohms Adjust................................9-1

3.	Ohms.............................................9-1

4.	DC Volts..................................................9-2

5.	AC Volts..................................................9-2

6.	Current....................................................9-2

7.	dBm........................................................9-2

X	PARTS LIST................................................................10-1
Hickok-3866-Manual-Page-1-Picture
Kostenlos herunterladen


Kommentare

Noch keine Kommentare vorhanden.

Kommentar Hinzufügen

* Pflichtfeld
(wird nicht veröffentlicht)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Which word in this sentence is bold?
 
Die Antwort lautet:
 
Informiere mich via E-Mail über neue Kommentare.
 
Meine Daten auf diesem Computer.
 
 
Powered by Commentics