Fluke 2280 Series Sonstiges
Hersteller:
Modell:
2280 Series
Datum:
1985
Kategorie:
Gruppe:
Beschreibung:
Data Logger

Information

The 2280 Series Data Logging System consists of a hardware configuration controlled by a menu-driven programming and operating scheme. The hardware configuration includes a 2280 mainframe, and may, depending on the applications being supported, include any assortment of option assemblies. In addition, one or more 2281A Extender Chassis may be used for more remote connections to the data logging environment. The programming and operating scheme involves substantial pre-programmed capabilities, all accessed directly from either a front panel keyboard or a remote controller. Distributed System Design The 2280 Series Data Logger makes use of a distributed system design that allows great flexibility in hardware placement. Any of the serial link option assemblies (and respective connector assemblies) can be installed in a remote 2281A Extender Chassis. The 2281A can be installed up to 1 kilometer from the 2280. All measurements and conversions can be completed at the remote location, with serial data consnunications occurring over a single cable. This system is quite efficient: external measurement wiring is minimized and accurate communication in electrically noisy environments is assured.

mehr

Bedienungsanleitung
Dokumenttyp:
Bedienungsanleitung
Seiten:
568
Größe:
14.19 Mbytes (14880302 Bytes)
Sprache:
english
Revision:
Dokument-ID:
758292
Datum:
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
2016 02 08
MD5:
2eb263b7f59f6e06da4a086eceba4132
Downloads:
944

Information

Section 1 How to Use This Manual Introduction ... 1-2 Organization ... 1 -4 The 2280 Series Data Loggers ... 1-6 How to Use the Manual Set ... 1-6 User Guide ... 1-6 System Guide ... 1-6 Service Manual ... 1-7 Notation Conventions ... 1-7 Section 2 Data Logging Applications Introduction ... 2-3 Data Logging Systems ... 2-3 The 2280 Series Data Logging System ... 2-6 General ... 2-6 Distributed System Design ... 2-6 Mainframe ... 2-8 Option Assemblies ... 2-8 Serial Link Option Assemblies ... 2-9 Connector Assemblies ... 2-12 Interface Option Assemblies ... 2-14 Other Option Assemblies ... 2-15 Extender Chassis ... 2-15 Accessories ... 2-17 Applications ... 2-18 Temperature Measurement Using Thermocouples ... 2-18 Temperature Measurement Using RTDs ... 2-19 Temperature Measurement Using Thermistors ... 2-20 AC Voltage Measurement ... 2-20 DC Voltage Measurement ... 2-20 Current Measurement ... 2-20 Resistance Measurement ... 2-21 Frequency Measurement ... 2-22 Totalizing Measurement ... 2-22 Strain Measurement ... 2-22 Digital and Status Inputs ... 2-22 Status Outputs ... 2-23 Analog Outputs ... 2-23 Using the 2280 Series Data Logger ... 2-23 Overview ... * ... 2-23 The Programming Form ... 2-24 The Menu System ... 2-24 Moving Through the Menus ... 2-2? How the 2280 Series Data Loggers Differ ... 2-29 Features ... 2-29 Permissible Option Configurations ... 2-30 Summary ... 2-31 Section 3 Installation - Mainframe Introduction ... 3-3 General Information ... 3-3 Shipping ... 3-3 Unpacking ... .· ... 3-4 Physical Layout ... 3-4 Physical Installation ... 3-7 Selecting a Location ... 3-7 Rack Mounting ... 3-8 Attaching the Front Panel Doors ... 3-11 Power Connections ... 3-11 Line Voltage * ... 3-11 Battery Operation ... 3-13 Hardware Configuration ... 3-13 Extender Chassis (2281 ) ... 3-14 Option Assemblies ... 3-15 New Installation ... 3-15 Previously Installed ... 3-15 Addressing ... 3-15 A/D Converter ... 3-15 Digital I/O Assembly ... 3-16 Analog Output ... 3-18 Counter/Totalizer ... 3-18 IEEE-488 Interface ... 3-19 Other Switch Selections ... 3-19 Jumpers ... 3-19 External Connections ... 3-20 Master Alarm Output/Trigger Input ... 3-21 Programming ... 3-21 Operator Maintenance ... 3-22 Introduction ... 3-22 Fuse Replacement ... 3-22 General Cleaning ... 3-23 Paper Replacement ... 3-25 Service Information ... 3-27 Section 4 Installation - Options and Accessories AC Voltage Input Connector (2280A-160) ... 162-1 RTD/Resistance Scanner (2280B-163) ... ____163-1 Transducer Excitation (2280A-164) .. ... 164-1 Counter/Totalizer (2280B-167) ..___ ... ____167-1 Digital I/O Assembly (2280A—168) ... 168-1 Status Output Connector (2280A-169) ... 169-1 Analog Output (22808-170) ... 170-1 Current Input Connector (2280A—171) ... 171-1 Transducer Excitation Connector (2280A-174) . 174-1 Isothermal Input (2280A-175) ... 175-1 Voltage Input Connector (2280A-176) ... 176-1 RTD/Resistance Input Connector (2280B-177) .. 177-1 Digital/Status Input Connector (2280A-179) .. 179-1 Advanced Math Processor (2280A-211) ... 211-1 DC Cartridge Tape (2280A-214) ... 214-1 RS-232-C Interface (2280A-341) ... 341-1 IEEE-488 Interface (2280A-342) ... 342-1 2281A-402 Extender Chassis Cable ... 402-1 2281A-403 Connector Pair for -402 Cable ... 403-1 2281A-431 Extender Chassis Power supply ... 431-1 Y2044 Rack Slide Kit ... Y2044-1 Y2045 Rack Mount Kit ... Y2045-1 Y2047 Serial Link Multiconnect ... Y2047-1 Section 5 Using the 2280 Temperature Measurement Using Thermocouples ... 5a-1 Using RTDs ... 5a-13 Using Thermistors ... 5a-39 Voltage Measurement AC Voltage ... 5b-1 DC Voltage ... 5b-7 Current Measurement ... 5c-1 Resistance Measurement ... 5d-1 Frequency Measurement ... 5e-1 Totalizing Measurement ... 5f-1 Strain Measurement ... 5g-1 Digital Input ... 5h-1 Status Input ... 5h-9 Status Output ... 5i-1 Analog Output ... 5j-1 Writing Control Algorithms ... 5J-7 Section 6 Appendices 6a. Glossary ... 6a-1 6b. Sales and Service Centers ... 6b-1 6c. ASCII/IEEE-488 ... 6c-1 6d. 2285B Documentation ... 6d-1 6e. 2280A Documentation ... 6e-1 6f. Connector Pinouts ... 6f-1 6g. System Specifications ... 6g-1 6h. Cartridge Tape Handling ... 6h-1 6i. Cartridge Tape Format ... 6i-1 6 j . Memory Usage ... 6 j -1

mehr

Bedienungsanleitung
Dokumenttyp:
Bedienungsanleitung
Seiten:
452
Größe:
11.18 Mbytes (11718689 Bytes)
Sprache:
english
Revision:
Dokument-ID:
758276
Datum:
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
2016 02 08
MD5:
7eb7375ac3a0611ea9631c2b6cfea865
Downloads:
749

Information

1 GETTING STARTED ... I~1 Overview . ... ... ... . 1-2!·;· Introduction ... a ... 1-3 , Manual Organization 1-4·".·..· Connecting the Units .. 1-5 ' Additional Hardware . 1-5 Establishing Communications „ . 1-6' Making a Backup Diskette ... 1-6 Conventions of ProLogger . 1-7 How is ProLogger Structured ... 1-8 Using ProLogger for the First Time ... 1-9 Error Conditions ... 1-11' Getting Stopped ... ... . 1-11. PROLOGGER OFF LINE FONCTIONS ... 2~1 Introduction ... ο ... 2-2 Off Line Windows ... .2-3 Main Menu ... 2-4 Set up ... 2-5 Port Select ... ο ... . 2-6 Parameters ... 2-7 Baud Rate ... 2“8 Sound ... ο ... 2-9 Sound Edit ... 2-1.0. Octave ... 2-11 Disk Utility ... 2-12' Select Type ... ... ... 2-13 File Select ... 2-14 Maine File ... 2 «*15· Directory . 2-I6 Delete File ... * 2-I7 File Select ... 2-14 Name File ... 2-15 Copy File ... 2^X0 Down Load ... 2-l§ File Select ... ... ο ... 2-14 Name File ... ... ... 2^15 Lotus Format ... 2-21 File Select ... ... . 2-14 Name File ... 2-15 Select Cell ... 2-22 2280B ... 3-1 CONTENTS PROLOGGER ON LINE COMMUNICATIONS Introduction Display Window Program Status Window Printer/Recording Window »»«»» Function Keys Record . , Function Summary Notes on Operation Suggested 2280B Program Dos and Don!ts

mehr

Serviceanleitung
Dokumenttyp:
Serviceanleitung
Seiten:
710
Größe:
52.69 Mbytes (55254485 Bytes)
Sprache:
english
Revision:
2
Dokument-ID:
753111
Datum:
1990 01 01
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
2018 01 12
MD5:
8161ab61b4653577ca65889a836fd922
Downloads:
3756

Information

How to Use This Manual Describes the organization and use of the Service Manual. General Information Describes the Data Logger and its available Accessories and options. Required test equipment, shipping, and factory service information are included here. Theory of Operation Covers the theory of operation for the Data Logger mainframe. Option assembly theory is contained in the individual option subsections of Sections 8, 9, and 10. Maintenance Describes maintenance of the instrument. Cleaning instructions and internal access procedures are included here. Troubleshooting Consists of diagnostic self-tests and performance tests designed to isolate a malfunction to the circuit board level. Component level troubleshooting may be performed using the Theory of Operation (Section 3) and Schematic Diagrams (Section 7). List of Replaceable Parts Contains parts lists for the Data Logger mainframe and gives parts ordering information. Option assembly parts lists are in the individual subsections of Sections 8, 9, and 10. Schematic Diagrams Presents Data Logger mainframe schematics on foldout pages. Schematics for option assemblies are located in the individual option subsections. Options -160 Through -169 Covers Options -160 through -169 in subsections ordered numerically by option number. Includes theory of operation, maintenance procedures, performance validation procedures, calibration instructions, schematics, and a replacement parts list. Covers Options -170 through -179 in subsections ordered numerically by option number. Includes theory of operation, maintenance procedures, performance validation procedures, calibration instructions, schematics, and a replacement parts list. Options -200 and Above Covers Options -200 and above in subsections ordered numerically by option number. Includes theory of operation, maintenance procedures, performance validation procedures, calibration instructions, schematics, and a replacement parts list. Appendices A Specifications B Fluke Service Centers C Manual Change Information D Differences Between 2280A 2280B 2285B and 2286A

mehr