Geräte Informationen:

Electro Scientific Industries 300 PVB Analog Multimeter
Hersteller:
Electro Scientific Industries
Modell: 300 PVB
Datum: 1965
Kategorie: Messgeräte
Gruppe: Analog Multimeter
Beschreibung: Potentiometrie Voltmeter Bridge
Informationen:
                                    The ESI Model 300 Potentiometrie Voltmeter Bridge is a
battery-operated multiple-use dc measurement instrument. It
combines in the same case a five- range potentiometric
voltmeter, a three-range precision voltage source, an
eight-range ammeter, a ten-range Kelvin double bridge for
two-, three-, or four-terminal resistance measurements, a
four-terminal resistance comparison bridge, a ratiometer,
and a high-sensitivity electronic null detector.

Folgende Anleitungen sind für obiges Gerät verfügbar:

Electro Scientific Industries -- 300 PVB -- Service- und Bedienungsanleitung
Dateiname: ESI-6665-Manual-Page-1-Picture
Dokumenttyp: Service- und Bedienungsanleitung
Seitenanzahl: 62
Dateigröße: 8.83 Mbytes (9262777 Bytes)
Sprache: Englisch
Revision: revised
Dokument-ID/Nummer:
Datum: September 1965
Qualität: Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
MD5: 382080ebd3b7507fb3f59afd2430988c
ed2kID: 33212a2ff34d74525a5d31e810ba38bd
Downloads: 56 seit 11 Mai 2015
Informationen:
I INTRODUCTION
1.1 DESCRIPTION 1-1
1.2 SPECIFICATIONS 1-2
1.3 APPLICATIONS 1-3
II OPERATION
2.1 GENERAL 2-1
2.1.1 Controls, Connections and Indications 2-1 2. 1.2
Battery Life and Battery Check 2-3
2.1.3 Null Balancing 2-4
2.1.4 Meter Interpolation 2-5
2.1.5 Kelvin Klips 2-5
2.2 NORMAL OPERATION 2-7
2.2.1 Voltage Measurement 2-7
2.2.2 Standard Voltage Source 2-8
2.2.3 Current Measurement 2-9
2.2.4 Resistance Measurement 2-11
2.2.5 Ratio Measurement 2-12
2.2.6 Comparison Bridge 2-13
2.3 EXTENDED OPERATION 2-16
2.3.1 External Detector 2-16
2.3.2 External Generator 2-16
2.3.3 External Current Shunt 2-17
2.3.4 External Voltage Dropping Resistor 2-19
2.4 AUXILIARY OPERATION 2-21
2.4. 1 Null Detector Auxiliary Operation 2-21
2.4.2 Main Decade Auxiliary Operation 2-21
2.4.3 Internal Resistor Auxiliary Use 2-21
2.5 GENERATOR POWER 2-23
III THEORY
3.1 GENERAL 3-1
3.1.1 The Kelvin Bridge 3-1
3.1.2 The Potentiometrie Voltmeter 3-1
3.2 SCHEMATIC DIAGRAMS 3-2
IV MAINTENANCE
4.1 CHECKOUT AND STANDARD CELL CALIBRATION 4-1
4.1.1 Mechanical Checks 4-2
4.1.2 Battery Load Test 4-2
4.1.3 Null Detector Sensitivity Test 4-2
4.1.4 Stability Test 4-3
4.1.5 Main Decade Linearity Test 4-3
4.1.6 Internal Standard Resistor Test 4-4
4.1.7 Standard Cell Calibration 4-4
4.2 TROUBLESHOOTING 4-5
4.2.1 Troubleshooting Table 4-5
4.2.2 Removing the Instrument Case 4-7
4.3 REPLACEMENT PARTS 4-10
ESI-6665-Manual-Page-1-Picture
Kostenlos herunterladen


Kommentare

Noch keine Kommentare vorhanden.

Kommentar Hinzufügen

* Pflichtfeld
(wird nicht veröffentlicht)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Enter the third letter of the word castle.
 
Die Antwort lautet:
 
Informiere mich via E-Mail über neue Kommentare.
 
Meine Daten auf diesem Computer.
 
 
Powered by Commentics