Geräte Informationen:

Anritsu MS2601A Spektrumanalysator
Hersteller:
Anritsu
Modell: MS2601A
Datum: 1988
Kategorie: Messgeräte
Gruppe: Spektrumanalysator
Beschreibung:
Informationen:
                                    The MS2601A/J Spectrum Analyzer has a wide bandwidth from 9
kHz to 2.2 GHz which includes the video band. The RF input
impedance is 50 Ω for the MS2601A and 75 Ω for the MS2601J.
A synthesized system is used for the local signal. Also,
since an automatic calibration function is built in,
measurement error is reduced to 1/3 of conventional Anritsu
spectrum analyzers and very accurate measurements are
possible. The MS2601A/J operability is furthered by use of a
zone marker, a zone marker sweep, a frequency axis scroll, a
unique new counting method, and a PMC (Plug-in Memory Card)
which simplifies the measurement. Moreover, since PTA
(Personal Test Automation) can be built in, a high-speed
automatic measuring system can be configured easily.

Therefore, the MS2601A/J is very suited to productions line
for various components and electronic devices.

The MS2601A/J has also a quasi peak (QP) detector to measure
the EMI from data processing equipment.

■ Applications

The MS2601A/J can be used for development, adjustment,
inspection, and maintenance of electronic components and
devices in:

AM, FM mobile radio equipment MCA, personal radio equipment

Satellite broadcasting, TV equipment (tuners, converters, etc.)

Data processing equipment such as personal computers for EMI
(Electro-Magnetic Interference) measurement

Folgende Anleitungen sind für obiges Gerät verfügbar:

Anritsu -- MS2601A -- Bedienungsanleitung
Dateiname: Anritsu-5909-Manual-Page-1-Picture
Dokumenttyp: Bedienungsanleitung
Seitenanzahl: 598
Dateigröße: 6.80 Mbytes (7129384 Bytes)
Sprache: Englisch
Revision: 1
Dokument-ID/Nummer: 100N-14
Datum: Januar 1990
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: 61a65c418e3e86e5d031836bd23a0123
ed2kID: 098abd02795edde8cdd064ef4f8043dc
Downloads: 176 seit 02 Mai 2014
Informationen:
This operation manual consists of 12 sections and appendixes
outlined below:
Composition
Use
SECTION  SECTION  SECTION  SECTION	1  2  3  4	GENERAL 
PREPARATION  STARTING OPERATION AND SIMPLE PERFORMANCE
CHECKS  CALIBRATION AND PERFORMANCE TESTS	. SECTIONS 1 to 4
describe how prepare and evaluate the MS2601A/J (simple
checks or performance tests).  . SECTIONS 1 to 3 also give
background information for general operation of the MS2601A/J.
SECTION	5	OPERATION	. SECTION 5 is a detailed description of
the front and rear panel controls
SECTION	6	MEASUREMENT	shown in APPENDIX P.  Beginners should
read this section
SECTION	7	PRINCIPLES OF OPERATION	after reading SECTION 3. 
. SECTION 6 explains the typical measurement procedure.  .
SECTION 7 explains the MS2601A/J block diagram.
SECTION	8	GP-IB GENERAL	. These sections explain the GP-IB
programming for configuring an auto-
SECTION	9	GP-IB ADDRESSES	matic measurement system by
combining the MS2601A/J with a personal
SECTION	10	GENERAL FORMAT OF GP-IB DEVICE MESSAGE	computer
and other measuring instruments.
SECTION	11	DETAILS OF GP-IB DEVICE MESSAGE	
SECTION	12	PROGRAMMING	
APPENDIX A		to P	Data for operation manual
	Q	Front and rear panel controls explanation	The MS2601A/J
front and rear panel drawings and explanation are attached
as a foldout at the end of this operation manual.
Anritsu-5909-Manual-Page-1-Picture
Kostenlos herunterladen


Anritsu -- MS2601A -- Serviceanleitung
Dateiname: Anritsu-5910-Manual-Page-1-Picture
Dokumenttyp: Serviceanleitung
Seitenanzahl: 424
Dateigröße: 4.25 Mbytes (4457249 Bytes)
Sprache: Englisch
Revision: 1
Dokument-ID/Nummer: 100 N-9
Datum: Februar 1990
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: 4e4c63ebe0ccab4b59a831ac4a22d034
ed2kID: a56efffdd60c9bb6a9e4854922c1acd8
Downloads: 151 seit 02 Mai 2014
Informationen:
This manual describes how to troubleshoot and adjust the
MS2601A/J Spectrum Analyzer. It is composed of the following
sections.

SECTION 2 MECHANICAL CONFIGURATION

This section describes the mechanical parts and how to
disassemble each unit (PCB etc.)

SECTION 3 TROUBLESHOOTING AND ADJUSTMENT

This section describes the operation of each circuit,
troubleshooting procedures, and adjustment procedures.

SECTION 4 CALIBRATION OF COMPENSATION DATA

This section describes how to enter the compensation data
for internal characteristics after repair.

SECTION 5 REPLACEABLE PARTS

This section includes the parts list and describes how to
order replaceable parts.
Anritsu-5910-Manual-Page-1-Picture
Kostenlos herunterladen


Kommentare

Noch keine Kommentare vorhanden.

Kommentar Hinzufügen

* Pflichtfeld
(wird nicht veröffentlicht)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Out of 56, 14 or 27, which is the smallest?
 
Die Antwort lautet:
 
Informiere mich via E-Mail über neue Kommentare.
 
Meine Daten auf diesem Computer.
 
 
Powered by Commentics